7. Pour ALL of the provided media (fire ice) into the burner pan. Burner MUST be completely
covered to ensure the appliance functions properly and safely. Remove any fire ice on top of the
ignition well. See Figure 6.
8. Slide the tank drawer out and place the LP tank in the drawer. Connect the regulator as shown
in Figure 7.Turn the black handle clockwise to tighten. Turn the handle counterclockwise to
remove. The hose must point down. Check that the valve is turned all the way clockwise to the
"OFF" position. Open the tank valve. Apply a solution of soapy water to the tank-regulator
connection and to the valve-hose connection to check for leaks. If soap bubbles continue to form,
the connection has a leak. If a leak is found, close the tank valve and tighten all connections.
NEVER USE A FLAME TO CHECK FOR LEAKS.
9. Tighten the threaded knobs (G) found on the tank tray (Figure 8) so that the LP tank cannot
move from side to side. Do not remove the plastic cap from the end of the threaded section.
Figure 6
Figure 7
Figure 8
8