PROBLEM
Burner won't light
Burner won't stay
lit after lighting

TROUBLESHOOTING GUIDE

CAUSE
No Propane Gas at Burner
No Spark at Electrode
Lack of oxygen
Thermocouple not in flame
Thermocouple connection
at the main control valve is
loose
No Fire Ice on Burner
REMEDY
Check that gas tank valve is open.
Turn control knob to "ON" and push
control knob in. Make sure tank has
propane gas.
Check that AA battery is installed with
negative (-) end first and has a charge.
Check that the wire is connected to the
ignition module. Check that the
electrode is not cracked or broken.
Remove excess fire ice from around
the ignition well.
Check that the tip of the thermocouple
is even with the top of the ignition well.
Remove any fire ice from the ignition
well.
Tighten the thermocouple nut at the
back of the valve.
Cover the burner with fire ice per the
instructions.