7. STARTUP AND OPERATION

7.1. Preliminary checks before start-up of the
pump
Do not start the device in case of damaged parts.
EN
7.2. First starting
1. Be sure that the pump is correctly primed, then
gently open one tap
2. Connect the IDROMAT to the electric supply, the
voltage LED will lit (POWER
3. The pump starts working automatically and within a
period of 20-25 seconds the pressure gauge (only for
IDROMAT 5) will reach the maximum pump pressure.
While the pump is on, the led
pump doesn't start or it doesn't reach the pressure,
reset with the button
4. Close the tap indicated on point 1;after 8-10 seconds
the pump will stop. The voltage LED (
only one to remain on.
Any problem after this procedure will be due to a
defective pump priming.
7.3. Setting the restart pressure values (IDROMAT
5e)
The device is calibrated in factory to 1,5 bar, to change
the value keep the button Set pushed for 3 seconds for
one or more times.
to the value selected. The pump stops if the pressure
generated by the same fails to reach the values
indicated above. The pump restarts but does not start
working if the height of the water column is higher than
the quotas shown in the table at page 9).
7.4. Automatic restart and anti-jamming function
In case of stop due to a lack of aspiration water, the
device starts 10 double attempts of restart of about 5
seconds each one, during the next 24 hours from the
block. This to permit, if possible, the recharge of the
pump. After the last attempt of failed restart, the device
stays in alarm (red led FAILURE
for a new manual restart through the pushbutton
(RESET
). In case the pump will be stopped for 24
consecutive hour (except in presence of FAILURE
) the device restarts the motor automatically of about
5 seconds (antiblockage function). In case of energy
interruption, the device restarts automatically at the
energy return.
Page 12 / 52
).
is lightened. If the
.
) will be the
The green LED will light up next
intermittent) waiting

7.5. Switch off

The device must be switched off every time
there are faults.
The device is designed for continuous working. The
shutdown takes place only disconnecting the power
supply according to the specific disconnection
methods. (Paragraph 6.7).

8. DISPOSAL

Dir. 2012/19 EU (WEEE)
Observe the local regulations and dispose of any
control gear accordingly.
This product contains electrical and electronic
components and should be disposed accordingly.
Separate the components using anti-cut water
resistant gloves.
Is preferred to help to make a further use or dismantling.
Observe the local regulations and dispose the device
accordingly with the international rules for environment
protection.
ISTR_IDROMAT_Rev02 - Operating Instructions