BA100
25
26
M5
27
28
29
30
M6
31
J2_RX
26
8K2
FIG. 2
29
26
FIG. 3
29
8K2
26
FIG. 4
29
FUNCTION PROGRAMMING (DIP SWITCH SW1)
DIP
STATUS
DIP 1
OFF
STEP-BY-STEP WITH STOP
DIP 2
OFF
DIP 1
ON
STEP-BY-STEP
DIP 2
OFF
DIP 1
OFF
CONDOMINIUM
DIP 2
ON
DIP 1
ON
DIP 2
ON
PHOTO 2
PHOTOCELL 2 input (N.C.)
SAFETY DEVICE input
•If not used leave the 8K2 resistor in place between terminals 26 and 29 (Fig.2).
•If using a safety device already with 8K2 resistor connected between
terminals 26 and 29 (Fig.3) remove the resistor fitted.
SAF. DEV
•If using a safety device with N.C. contact, connect the 8K2 resistor provided
in series to the contact (Fig.4).
ENCODER
Non implementato
COM
COMMON INPUTS/OUTPUTS
COM
COMMON INPUTS/OUTPUTS
GND
ANTENNA GROUND input
ANTENNA SIGNAL input
ANT
Connector for plug-in receiver
WITHOUT
CONDUCTIVE EDGE
CONDUCTIVE EDGE
WITH RESISTANCE
8K2 INTEGRATED
CONDUCTIVE EDGE
WITH N.C. CONTACT
FUNCTION
DESCRIPTION
I Start pulse
II Start pulse
III Start pulse
IV Start pulse
I Start pulse
II Start pulse
III Start pulse
During opening it does not receive other Start commands after the first
one; during Pause subsequent Start commands reload the pause time
I Start pulse
Subsequent Start pulses
Pause from opening limit switch or opening time
Start pulse during pause
Subsequent Start pulse
Buttons on the board:
If Start button is held down
If Close button is held down
DEAD MAN
From terminal board:
Closing the Start contact
Closing the PHOTO 1 contact and setting DIP1 of SW2 to OFF the door closes
OPEN
STOP (
will not reclose automatically
CLOSE
OPEN
OPEN
CLOSE
OPEN
OPEN
Uninfluential
Reloads the pause time (if DIP 6 ON)
or CLOSES (if DIP 6 OFF)
OPEN
OPEN
CLOSE
OPEN
13
UK
)