FINAL CHECKS AND TESTING
1 Check the electrical connections: improper connection may be harmful to both the control unit and the
operator.
2 Check correct setting of the dip switches according to requirements.
3 Check that the red LEDs of the normally closed contacts are on and the green LED of the normally open
contact off.
4 Check by tripping the limit switches that the corresponding LEDs go off.
5 Check by passing across the range of the photocells that the corresponding LEDs go off.
6 Check by tripping the safety devices that the corresponding LEDs go off.
7 Set the gate to halfway its travel and lock the motor. Remove any obstacles in the range of action of the gate
and then give a START command. Upon the first START command, an opening phase starts; check that the
gate moves in the correct direction. If not, invert the wires in the MOTOR OPEN (5) - MOTOR CLOSE
(7)terminals.
8 Adjust the trimmer TR3 (PAUSE) setting the desired pause time (at max clockwise 200 seconds are
obtained)
9 Adjust the trimmer TR2 (CLOSE) setting the desired closing time.
10 Adjust the trimmer TR5 (OPEN) setting the desired opening time.
11 During motion turn the trimmer TR4 (FORCE) until finding the desired force/speed value.
12 During slow motion, turn the trimmer TR1 (SLOW) until finding the desired force/speed value.
Remember to set the SW5 jumper to position 2-3 before activating normal operation, otherwise a
fault will be signalled during the SAFETY DEVICE TEST and the gate will remain locked.
BA100 DISPOSAL
Gi.Bi.Di advises recycling the plastic components and to dispose of them at special
authorised centres for electronic components thus protecting the environment from
polluting substances.