14
UK
ON
DIP 3
OFF
ON
DIP 4
OFF
ON
DIP 5
OFF
ON
DIP 6
OFF
DIP 7
OFF
DIP 9
OFF
DIP 7
OFF
DIP 9
ON
DIP 7
ON
DIP 9
OFF
DIP 7
ON
DIP 9
ON
ON
DIP 8
FAST CLOSING PHOTO 1
OFF
ON
DIP 10
OFF
DEFAULT SETTINGS (DIP SWITCH SW1)
DIP 1 and DIP 2 both OFF: Step-by-step with stop
DIP 3 OFF: Water hammer and pre-flashing deactivated
DIP 4 OFF: Safety device test disabled
DIP 5 OFF: Electromechanical motor
DIP 6 ON: Automatic closing enabled
DIP 7 AND DIP 9 BOTH OFF Deceleration disabled
DIP 8 OFF: Fast closing disabled
DIP 10 OFF: STOP enabled
NOTE 1 *
If motion is inverted from opening to closing and vice versa, the opening and closing times will be the same in the case of an electromechanical
configuration, but different in the case of a hydraulic configuration in order to take into account the different speed at which the operator runs in
the two phases. In some hydraulic applications where the operators run at the same speed during opening and closing (e.g. FLOOR 810), it is
advisable to enable electromechanical configuration.
WATER HAMMER
AND PRE-FLASHING
SAFETY DEVICE TEST
HYDRAULIC MOTOR
AUTOMATIC CLOSING
NO DECELERATION
DECELERATION WITH
LIMIT SWITCH
5-SECOND
DECELERATION
10-SECOND
DECELERATION
NO STOP
Enables pre-flashing during opening and closing for 3 seconds before moving
the door. After pre-flashing a 1-second closing pulse is given (water hammer)
to aid release of the electric lock (during opening only).
Disables the water hammer and pre-flashing function
Enables the safety device TEST before activating the opening and closing cycle.
The cycle can only start if the devices work perfectly, if not, three prolonged
flashes indicate the fault.
NB: After the start phase, set SW5 to position 2-3
Disables the safety device test.
The operator is hydraulic
The operator is type electromechanical
Enables automatic closing after the pause time adjustable with the trimmer TR3
PAUSE between 2 and 200 seconds.
Disables automatic closing.
Deceleration function disabled
Enables deceleration during both opening and closing when the respective limit switch is
intercepted. If the jumpers JP1 and JP2 are closed, the deceleration time can be
adjusted from 1 to 33 seconds; if the jumpers are open, the times can be adjusted from
1 to 16 seconds. The adjustment is made with the trimmers OPEN TR5 and CLOSE
TR2. NB. WITH THIS FUNCTION THE LIMIT SWITCHES DETERMINE
DECELERATION START
Enables deceleration during both opening and closing 5 seconds before the end
of the run time. In this case, pay attention to adjustment of the TR2 / TR5 run
times.
Enables deceleration during both opening and closing 10 seconds before the end of the
run time. In this case, pay attention to adjustment of the TR2 / TR5 run times.
Reduces the pause time to 1.5 seconds after intervention of the photocells.
Disables the fast closing function.
Disables the STOP command
Enables the STOP command