POWERS OF COMMON APPLIANCES
Electric equipment
Washing
machine
Electric
fan
Air
condition
2HP
The starting powers of the appliances are far more higher than the operation powers. Please read the labels of the electric
equipment for reference. The total power of the loads should not exceed the rated power of the generator.
MAINTENANCE
Maintenance
Good maintenance is the best guarantee of safe, economical
and fault-free operation. And it also contributes
to environmental protection.
Maintenance schedule is as follows:
Schedule for
regular
maintenance
Inspect
the oil level
Engine
oil
Replace
Inspect
Air
cleaner
Clean
Fuel
switch
Clean
sediment
cup
Spark
Clean
plug
Valve
Readjust
clearance
Cylinder
Wash
head
Fuel tank
Wash
and
strainer
Fuel tube
Replace
(1) Maintenance should be conducted frequently if the unit is
used in dusty places.
(2) Maintenance should be conducted by the franchised
dealer.
(3) When the unit is used frequently, please conduct the
maintenance according to the above mentioned intervals
so as to ensure the long-term usage of the generator.
Rated
Starting
power (W)
power (W)
250
500
50
100
1600
3200
(1)
Replace
Every 300 hours (2)
Every 2 years (2)
Every 2 years (2)
Electric equipment
Electric
welder
Electric
hammer
Water
pump
• Replace the engine oil
Oil filter
cap
Remove the oil draining bolt and drain the long time stored
oil. Tighten the oil draining bolt and twist off the oil dipstick.
Fill in appropriate amount of oil via the oil dipstick and keep
the oil lever between MIN and Max.
• Clean the air cleaner
Air cleaner
cover
Clip
(2)
Air cleaner
1 Remove the clip of the air cleaner cover and open it.
2 Inspect the cleaner element and ensure that it is sound
and clean.
3 If the foam cleaner element is dirty, spray some household
cleaning agent onto the cleaner element. Scrub it for
several minutes and rinse it with warm water. If the
cleaner element is damaged, please replace a new one.
10
Rated
power (W)
2500
1000
800
Upper
level
Oil drain
bolt
element
Starting
power (W)
5000
1500
1200
Element