13 After Finishing Work

13.1
After finishing work
► Switch off blower and remove battery.
► If the blower is wet: allow blower to dry.
► If the battery is wet: allow battery to dry.
► Clean blower.
► Clean battery.

14 Transporting

14.1
Transporting the blower
► Switch off the blower and remove the battery.
Carrying the blower
► Carry blower by the control handle in one
hand.
Transporting the blower in a vehicle
► Secure the blower so that it cannot topple over
and cannot move.
14.2
Transporting the battery
► Turn off the blower and remove the battery.
► Check that the battery is in a safe condition.
► Pack the battery in packaging in such a way
that it cannot move inside the packaging.
► Secure the packaging so that it cannot move.
The battery is subject to the Carriage of Danger‐
ous Goods regulations. The battery is classified
as UN 3480 (lithium ion batteries) and has been
tested pursuant to UN Manual Tests and Criteria
Part III, Subsection 38.3.
The transport regulations can be found at
www.stihl.com/safety-data-sheets.

15 Storing

15.1
Storing the blower
► Switch off blower and remove battery.
► The blower should be stored in such a way
that the following conditions are fulfilled:
– The blower is out of the reach of children.
– The blower is clean and dry.
15.2
Storing the Battery
STIHL recommends keeping the battery in a
charging state between 40% and 60 % (2 green
LEDs lit).
► The battery should be stored in such a way
that the following conditions are fulfilled:
– The battery is out of the reach of children.
– The battery is clean and dry.
– The battery is in an enclosed space.
24
– Battery is stored separately from the blower.
– If the battery is stored in the charger, dis‐
connect the mains plug and store the bat‐
tery at a state of charge between 40% and
60% (2 lit green LEDs).
– The battery is in a temperature range
between - 10 °C and + 50 °C.
NOTICE
■ If the battery is not stored as described in this
user manual, the battery may become deeply
discharged and irreparably damaged.
► Charge a discharged battery before storing
it. STIHL recommends keeping the battery
state of charge between 40% and 60% (2 lit
green LEDs).
► Store the battery separately from the
blower.

16 Cleaning

16.1
Cleaning the blower
► Switch off the blower and remove the battery.
► Clean blower with a damp cloth.
► Clean vents with a paintbrush.
► Remove foreign objects from the battery com‐
partment and clean the battery compartment
with a damp cloth.
► Clean the electrical contacts in the battery
compartment with a paintbrush or soft brush.
► Clean the shield with a paintbrush or soft
brush.
16.2
Cleaning the Battery
► Clean the battery with a damp cloth.

17 Maintenance and Repairs

17.1
Servicing and Repairing the
Blower
The blower cannot be serviced or repaired by the
user.
► If your blower has a malfunction or is dam‐
aged or requires servicing: Contact your
STIHL servicing dealer.
17.2
Servicing and Repairing the
Battery
The battery requires no servicing and cannot be
repaired.
► If the battery has a malfunction or is damaged:
Replace the battery.
13 After Finishing Work
0458-824-9821-B