Connecting Ic20, Ic40, Ic60 Power Center To Intellitouch, Easytouch Or Suntouch System - Pentair INTELLICHLOR IC15 Guía De Instalación Y Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

24
Connecting the IntelliChlor
®
IntelliTouch
, EasyTouch
To operate IntelliChlor SCG with the IntelliTouch, EasyTouch or SunTouch system, connect a four wire cable
from the IntelliChlor SCG Power Center to the IntelliTouch, EasyTouch or SunTouch load center. Note: Only
one IntelliChlor cell can be installed per system. An alternate connection can be made by splicing anywhere
along the four wire connection that connects the IntelliTouch or EasyTouch Control System indoor control panel
to the load center.
Note: See the following manuals for IntelliChlor SCG operating instructions when connected to a Pentair
Control System:
- IntelliTouch Control System User's Guide (P/N 521075)
- EasyTouch Control System User's Guide" (P/N 521044)
- SunTouch Control System User's Guide" (P/N 520785)
CAUTION - Wire the Power Center AC to the filter pump relay on the LOAD SIDE for maximum safety.
To connect IntelliChlor Power Center four wire cable to the IntelliTouch, EasyTouch or SunTouch Control System
load center:
WARNING - Switch OFF main system power to the Load Center before making any connections.
1. Remove the cover screw securing the Power Center cover. Remove the cover.
2. Run a UL approved four conductor cable (22 AWG) from the IntelliChlor Power Center to the Load
Center. The preferred wire color scheme is red, yellow, green, and black.
3. Remove the cover screw securing the Power Center cover. Remove the cover.
4. Remove one (1) of the knockouts from the underside of the Power Center.
5. Route the four conductor cable up through the lower hole.
6. Strip back the cable conductors 1-1/4 in. Insert the wires into the screw terminals (provided in the
kit). Secure the wires with the screws. Make sure to match the color coding of the wires:
Red = +15, Yellow = +DT, Green = -DT, and GND = Black.
7. Plug the screw terminal onto the four (4) pins located on the Power Center board.
8. Reinstall the cover and secure with the cover screw.
9. Proceed to "Connecting IntelliChlor to an IntelliTouch Control System," on page 25, "Connecting
IntelliChlor to an EasyTouch Control System," on page 26, and "Connecting an IntelliChlor SCG to
a SunTouch Control System," on page 26.
®
IntelliChlor
Salt Chlorine Generator Installation and User's Guide
®
IC20, IC40 or IC60 SCG Power Center to an
®
or SunTouch
Conduit knockout
®
Control System
IntelliChlor SCG Power
Center (cover removed)
Screw terminal
1
G
N
D
B
L
K
2
-
D
T
G
R
N
3
+
D
T
Y
E
L
4
1
5
V
R
E
D
Screw terminal pin-outs

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Intellichlor ic20Intellichlor ic40Intellichlor ic60

Tabla de contenido