Model
EQX2 5002-S
EQX2 5002-SX
EQX2 6002-S
EQX2 6002-SX
EQX2 8002-SX
EQX2 10002-SX
Tab. 9. Circuit breaker gauge and cable cross-sections, by model.
1.
Steps for connecting the AC connector.
a.
Extract the AC connector from the accessory bag and dis-
assemble it, following the steps marked on Fig. 26:
Insert the plastic piece into the holes marked in red
and pull the connector head out.
The fully disassembled AC connector is shown below:
AC terminal head
Fig. 26. AC connector.
b.
According to the above table, select a suitable cable, re-
move the insulation sleeve from the AC cable about 50 mm,
and remove the insulation from the end of the L/PE/N ca-
bles about 8 mm, as shown in Fig. 27:
Cable diameter: 10-14 mm.
Fig. 27. Cable stripping.
c.
Insert the stripped end of the three cables into the cor-
responding hole of the terminal head (yellow-green cable
into the PE port, phase into the L port and neutral into the
N port). Pull from the cable to check that it is properly con-
nected, as shown in Fig. 28:
56
Cable (mm
)
Breaker (A)
2
6
40
50
10
63
Threaded sleeve
Cable gland
Stri pp e d le n g t h: 8 mm.
50 mm.
Allen wrench
Fig. 28. Inserting the bare wire into the terminal.
d.
According to the direction of the arrow, push the threaded
sleeve until it connects to the AC terminal head, and then
turn the cable gland clockwise to lock it, as shown in Fig.
29:
Fig. 29. Connecting and fastening the sleeve on the AC
terminal.
e.
Connect the AC connector to the inverter's AC terminal;
a click indicates that the connection is in place, as shown
in Fig. 30:
Fig. 30. Connecting the AC connector to the inverter's AC terminal.
f.
Insert the relevant AC circuit breakers in between,
as shown in the table below: