handle in your hand at all times even as it returns to the starting
position. Repeat this motion until the engine starts.
g) Allow the engine to run at suction for about 1-3 minutes to reach
operating temperature.
h) After the generator has warmed up, turn off the suction (turn the
throttle valve smoothly to the "OPEN" position). You can connect 230V
AC receivers to the sockets, observing the rule to connect in the order
starting from the receiver requiring the highest starting current to the
lowest. In the case of 12V receivers, connect them to the appropriate
poles before starting the generator, paying attention to the correct
polarity.
i) Turn the installation switch to the "ON" position and you can use the
connected receivers.
3.3.3 Switching off the generator
a)
Turn the installation switch to the "OFF" position.
b)
Also turn the ignition switch to the "OFF" position - this will turn off the
engine.
c)
Close the fuel valve - move its lever to the "OFF" position.
IMPORTANT: in the case of emergency generator shutdown: turn the ignition
switch to the "OFF" position - the engine will stop. Then close the fuel valve.
3.3.4 TRANSPORT AND STORAGE
If the equipment is not to be used again, cool it down completely before
transporting. For transport, it is advisable to empty the fuel tank to prevent
any fuel leakage during transport.
If the unit is not used for a period of 1-2 months, empty the fuel from the tank
or pour fresh fuel and add stabilizer to it.
If the unit is not used for more than a few months, additionally empty the
carburetor of fuel (dropping tank) and drain oil from the engine.
Do not keep fuel in the tank with stabilizer longer than recommended by the
manufacturer of this additive.