4-Prong Power Cord Directions:
• Thread the power cord and leads through the opening below the
terminal block.
• Secure the cord by attaching the strain relief over the cord insulation
jacket. (Strain relief must be placed on the "body" of the cord and not
on the "leads.") Place the strain relief such that the leads have enough
slack to connect to the terminal block without any stress or tension.
• Remove the 3 screws from the supply side of the terminal block.
• Remove the copper ground link connecting the neutral connection on
the terminal block to the chassis ground.
• Attach the power cord leads to the terminal block and chassis as shown:
• Replace the access cover when complete.
3-Prong Power Cord Directions:
• Thread the power cord and leads through the opening below the terminal
block.
• Secure the cord by attaching the strain relief over the cord insulation
jacket. (Strain relief must be placed on the "body" of the cord and not on
the "leads.") Place the strain relief such that the leads have enough slack
to connect to the terminal block without any stress or tension.
• Remove the 3 screws from the supply side of the terminal block.
• Attach the power cord leads to the terminal block as shown:
22
• Replace the access cover when complete.