START UP.
1. Open the gas passage of the regulator of the cylinder.
2. Press and turn the control knob to the PILOT position (90º anti-clockwise).
3. Press the control knob all the way down and hold for 60 seconds.
4. While pressing the control knob, press the IGNITION button repeatedly
until the pilot flame is lit.
5. Release the control knob after the pilot flame ignites.
NOTE.
- If the cylinder has just been replaced, keep the control knob pressed on the
PILOT position for at least one minute to purge the air in the gas lines.
- To light the pilot flame, make sure that the control knob is pressed
during the pressing of the IGNITION button. The control knob can be released after 5 seconds
after the pilot flame is lit.
- If the pilot flame does not turn on or off, repeat the process from step 3.
6. After lighting the pilot flame, turn the control knob to the maximum position and hold for
5 minutes or more before turning the control knob to the desired temperature position.
ATTENTION: Check that there are no cracks or breaks in the glass before use.
- This stove is for outdoor use only.
- Make sure you have sufficient ventilation.
- Maintain a minimum safety distance between the stove
and flammable materials as well as roof and wall.
- 1m minimum safety distance recommended.
- The stove must be located on firm and level ground.
- Do not use combustible combustible liquids near the stove.
- To protect the stove from strong winds, secure the base
to the ground with screws.
- Locate the stove at least one meter from the wall,
and one meter from the ceiling.
Off Position: OFF.
Pilot: Position to Ignicion.
HI: High Temperature.
Lo: Low Temperature.