STEP 7
7-1. Bring up the tank housing and rest it on the post plate.
7-2. Connect the end thread of inlet gas hose to the regulator.
7-3. Connect the regulator to the gas tank and tighten it with
adjustable wrench.
7-4. Put LPG gas tank on the stand.
LIST OF PROBLEMS / SOLUTIONS
PROBLEM
The pilot
flame does
not light
The pilot flame
does not stay lit
The burner
does not light
If the device shows any defect or problem of assembly or use, do not modify or
manipulate yourself any point that has not been contemplated in the instructions.
Contact your distributor to solve it
Rubber tube and regulator are not included with the main product.
You must purchase these accessories at a specialized store.

POSSIBLE CAUSE

Gas valve closed
Empty gas bottle
Blocked opening Air in
the duct's Loose
connections
Impurities in pilot tube.
Loose connections.
Thermocouple defective.
Gas leak.
Little gas pressure.
Low pressure.
Blocked opening
Control in Off position.
Thermocouple defective.
Flame pilot twisted or in
incorrect position.
.
STEP 7
Regulator
Gas tank
SOLUTION
Open the gas passage.
Change the gas bottle.
Clean or open the
opening Purge the air
Check
connections.
Clean impurities.
Check the connections.
Replace the thermocouple.
Check the connections.
Check that there is gas in cylinder.
Empty tank Replace. Clean and
open opening Put control in ON
position Replace the thermocouple
Locate the pilot in the correct
position and volley to try.