8.
IN terminal can be used to connect input signal(s) to the
keypad:
- If the keypad input is used as an intrusion zone, wire the
input terminal (IN) according to Figure 8. The keypad input
supports the same EOL values as the xGenConnect
control panel, including the special EOL settings available
in the panel Advanced settings under System > EOL
Resistor Value. See xGenConnect Installation and
Programming Guide for details.
Note:
Zone doubling functionality is not supported.
- If the keypad input is used to combine the door contact
(DC) and door Request to Exit (RTE) signals, wire the
input according to Figure 9.
This wiring requires the keypad parameter "RTE as
Note:
a next zone" to be enabled. Only 3.3 kΩ EOL resistors can
be used in this case. Other EOL resistance configurations
are not supported, and relevant panel settings are ignored.
- If the input is not used, the IN terminal does not require
an EOL resistor.
9.
The OUT terminal can be used to control the door lock
(DL) if the system supports door access features. Wire the
output terminal as shown in Figure 10.
10. If the keypad is the last device on the xGen bus cable,
enable the xGen bus termination by moving the bus
termination switch (DIP switch 1) to the On position. See
also "DIP switch" on page 2.
11. Attach the keypad to the mounting plate by sliding the top
of the keypad onto the clips located on the top of the
mounting plate. See Figure 7.
12. Gently push bottom side to attach the clips.
13. Tighten the bottom screw to fix the keypad to the mounting
plate.
For keypad programming, see xGenConnect Installation and
Programming Guide.
See NXG-183x Keypad User Manual for keypad operation
details.
Firmware
The keypad is remotely upgradeable using DLX900, or locally
with the USBUP-EUR-V2 service tool via the USBUP port on
the keypad (Figure 5, item 1).
Specifications
Compatibility
xGenConnect panel series
Code combinations
10 000 to 100 000 000 (4 to 8 digits)
There are no invalid code combinations.
Voltage
9 to 15 VDC (provided by panel)
Current consumption (at 13.7 V DC):
NXG-1830-EUR, NXG-1831-EUR: 90 mA
Nominal
NXG-1832-EUR, NXG-1833-EUR: 130 mA
Minimal (all lights off)
NXG-1830-EUR, NXG-1831-EUR: 35 mA
NXG-1832-EUR, NXG-1833-EUR: 40 mA
Maximum
NXG-1830-EUR, NXG-1831-EUR: 160 mA
NXG-1832-EUR, NXG-1833-EUR: 200 mA
Input
Resistive, wiring compliant with
xGenConnect panel inputs
P/N 466-5560-ML • REV F • ISS 13JAN23
Output
NXG-1832-EUR, NXG-1833-EUR only
Open collector type
Internal 10 kΩ pullup to Main PWR line
Max. load for OC sink
100 mA
Max. voltage connected
16 VDC
externally
Overcurrent protection
Built in
Mifare reader
NXG-1832-EUR, NXG-1833-EUR only
Carrier frequency
13.560 MHz
Bandwidth
1.696 MHz
42 dBμA/m
Maximum power output
Supported cards
NXG-180x-5 (compatible with Mifare
DESFire EV2, EV3)
Wiring
xGen 4-wire bus
0.05 to 2.50 mm², 14 to 30 AWG
≤2 m
Mounting height
Dimensions (W × H × D)
133 x 130 x 25 mm
Colour
NXG-1830-EUR, NXG-1832-EUR: White
NXG-1831-EUR, NXG-1833-EUR:
Anthracite
Weight
0.3 kg
−10 to +50°C
Operating temperature
Maximum relative
95% noncondensing
humidity
Serviceable parts
There are no serviceable parts

Regulatory information

Manufacturer
Placed on the market by:
Carrier Fire & Security Americas Corporation, Inc.
13995 Pasteur Blvd
Palm Beach Gardens, FL 33418, USA
Authorized EU manufacturing representative:
Carrier Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, Netherlands
Product warnings
THESE PRODUCTS ARE INTENDED FOR SALE
and disclaimers
TO AND INSTALLATION BY QUALIFIED
PROFESSIONALS. CARRIER FIRE &
SECURITY CANNOT PROVIDE ANY
ASSURANCE THAT ANY PERSON OR ENTITY
BUYING ITS PRODUCTS, INCLUDING ANY
"AUTHORIZED DEALER" OR "AUTHORIZED
RESELLER", IS PROPERLY TRAINED OR
EXPERIENCED TO CORRECTLY INSTALL FIRE
AND SECURITY RELATED PRODUCTS.
For more information on warranty disclaimers and
product safety information, please check
https://firesecurityproducts.com/policy/product-
warning/ or scan the QR code.
Certification
EN 50131-3
Security Grade 2, Environmental class II
Tested and certified by Telefication B.V.
European Union
NXG-1830-EUR, NXG-1831-EUR: Carrier Fire &
directives
Security hereby declares that this device is in
compliance with the applicable requirements and
provisions of the Directive 2014/30/EU and/or
2014/35/EU. For more information see
www.firesecurityproducts.com/en/page/caddx