General Safety Instructions - LaserLiner ActiveFinder XP Manual De Instrucciones

Ocultar thumbs Ver también para ActiveFinder XP:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 32
Completely read through the operating instructions, the
„Warranty and Additional Information" booklet as well as
!
the latest information under the internet link at the end
of these instructions. Follow the instructions they contain.
This document must be kept in a safe place and passed on
together with the device.
Function / Application
Non-contact tester for locating electrical voltage (230 VAC) in
cables, sockets, bulb sockets, fuses, control cabinet and system
components. Visual and acoustic signals as well as vibration
indicate whether a voltage is present.

General safety instructions

– The device must only be used in accordance with its intended
purpose and within the scope of the specifications.
– The measuring tools and accessories are not toys. Keep out of
reach of children.
– Modifications or changes to the device are not permitted, this will
otherwise invalidate the approval and safety specifications.
– Do not expose the device to mechanical stress, extreme
temperatures, moisture or significant vibration.
– If you are working with voltages higher than 24 V/AC rms / 60 V/DC,
exercise extreme caution. Touching the electrical conductors at
such voltages poses a risk of life-threatening electric shocks.
– If the device comes into contact with moisture or other conductive-
residue, work must not be carried out under voltage. At and
above voltages of 24 V/AC rms / 60 V/DC, the presence of
moisture creates the risk of life-threatening electric shocks.
– Use this device only within closed rooms, do not expose it to moisture
or to rain, since there is otherwise the risk of an electric shock.
– In overvoltage category IV (CAT IV - 1000 V), the voltage between
the test device and earth must not exceed 1000 V.
– Before taking any measurements, make sure that both the area to
be tested (e.g. a line), the test device and the accessories used
(e.g. connection cable) are in proper working order. Test the device
by connecting it to known voltage sources (e.g. a 230 V socket in
the case of AC testing).
– Clean and dry the device before use.
– The device must be disconnected from all power sources and
measuring circuits before opening the cover to change the
battery(ies) or fuse(s).
– The device must no longer be used if one or more of its functions
fail or the battery charge is weak.
– Observe the safety precautions of local and national authorities
relating to the correct use of the device and any prescribed safety
equipment (e.g. electrician's safety gloves).
08
EN

Publicidad

Tabla de contenido
loading

Tabla de contenido