Epic Presentation; Safety Warnings; Installation; Technical Characteristics - Pentax IPFC 109 Manual De Instrucciones

Ocultar thumbs Ver también para IPFC 109:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

1. EPIC presentation

EPIC is a control and protection device for pumping systems
based on the power supply frequency variation of the pump.
EPIC guarantees:
Energy and cost saving.
Simplified installation and lower costs of the system.
Extended durability of the system.
Increased reliability.
EPIC guarantees pump operation to maintain the pressure
constant according to the use conditions variations. This way,
the pump, or pump system, is activated only when required,
for the time required; as a result, energy waste is avoided and
its durability is longer.
At the same time, EPIC can:
Protect the motor against overload and dry operation
and
provide a relative alarm indication.
Activate soft start and soft stop to extend system du-
rability and reduce consumption peaks.
Connect to another EPIC device for combined opera-
tion
(COMBO).

2. Safety warnings

The manufacturer recommends reading the instruction manu-
Failure to comply with the recommendations provided in this
manual, and in general, with the universal safety standards,
may cause severe electric shocks or death.
The device must be connected to the mains via a switch/cut-
out switch in order to guarantee disconnection from the power
supply (even visual), before acting on the EPIC and on any
connected load.
Disconnect the EPIC from the power supply before acting on
the device and connected loads.
Never remove the cable gland plate or cover, before having
disconnected EPIC from the power supply and waited for at
least 5 minutes.
The EPIC system and pump must be accurately earthed be-
fore commissioning.
During the period in which EPIC is powered by the mains,
regardless of whether it is activating the load or is in standby
mode (digital deactivation of the load), the motor output termi-
nals remain live compared to the earth. This way, the opera-
4
als of his products carefully before
their installation and use.
Any operation must be performed
by qualified personnel.
tor is exposed to risks, as by seeing the load stopped, he/she
may operate on the device.
We recommend tightening the 4 cover screws with relative
washers before powering the device. Otherwise, the cover
earth connection may fail causing electric shock or death.
Avoid impacts to the product or extreme climatic conditions
during transport.
Make sure the product comes fully equipped with its accesso-
ries. In the event components are missing, immediately con-
tact the supplier.
Damage to the product due to transport, installation, or im-
proper use is not covered by the warranty of the manufac-
turer. Tampering with or disassembling any component will
automatically make the warranty void and null.
The manufacturer declines any liability for damage to persons
or objects due to improper use of his products.

3. Installation

EPIC can be mounted directly on the motor, replacing the
terminal box. Refer to the manufacturer for compatibility and
motor-EPIC coupling mode.
The device consists of two essential components.
Coupling base
Heat sink with electronic board
The heat sink part can be rotated by 180° to meet t he appli-
cation with vertical axes pumps.

4. Technical characteristics

Vin
Max
+/- 15%
Vout
[VAC]
[VAC]
1 x 230
3 x 230
P.F. line side: 1 (in compliance with EN61000-3-2).
Power supply frequency: 48 - 62 Hz .
Max. operating temperature at nominal load: 40° C
(104 ° F).
Maximum humidity relative to the installation environ-
ment: 50% at 40° C without condensation.
Max. altitude at nominal load: 1000 m.
Protection rate: IP55 (NEMA 4).
Connectivity: RS 485 serial port for COMBO opera-
tion.
Max
Max I
P2
I line
out
typical
[A]
[A]
[KW]
11
7.5
1.5
Weig
ht
[kg]
2.5

Publicidad

Tabla de contenido
loading

Tabla de contenido