EAS ELECTRIC EMCH Serie Manual De Instrucciones página 92

Ocultar thumbs Ver también para EMCH Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

When connecting to the power supply terminal, use the circular wiring terminal with the insulation casing (see
Figure 9.1).
Use power cord that conforms to the specifications and connect the power cord firmly. To prevent the cord
from being pulled out by external force, make sure it is fixed securely.
If circular wiring terminal with the insulation casing cannot be used, please make sure that:
Do not connect two power cords with different diameters to the same power supply terminal (may cause
overheating of wires due to loose wiring) (See Figure 9.2).
+
Figure 9.1
Power Cord Connection of cascade system
Use a dedicated power supply for the indoor unit that is different from the power supply for the outdoor unit.
Use the same power supply, circuit breaker and leakage protective device for the indoor units connected to the
same outdoor unit.
Power Supply
Circuit Breaker
Manual switch
Circular wiring
terminal
Insulation tube
Power cord
Figure 9.3
31
: Copper wire
Proper power wiring connections
Figure 9.2
Wire Distribution Box
......
V.1

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Emch-09r1Emch-12r1Emch-16r3

Tabla de contenido