To remove the bandsaw to sharpen or replace it, proceed as follows.
1 - Disconnect the power cord from the electrical mains;
2 - Unscrew the knobs to open the guard (E).
3 - Rotate the knob (F) counter-clockwise to fully loosen the bandsaw (C1).
4 - Remove the bandsaw and sharpen or replace it with a new one.
5 - Use the knob (F) to adjust bandsaw tension.
6 - Make sure the bandsaw is centred and in line with the blade guide blocks (H).
7 - To centre the bandsaw, loosen the knobs (G), lightly rest the blocks (H) against the
blade and tighten the knobs.
8 - Close the guard (E) and tighten the knobs.
9 - Connect the power cord to the electrical mains;
APPLIANCE CLEANING
Before cleaning the appliance (at the end of the day or when necessary) turn the power
off or unplug the power cord.
– Accurately clean the work surface and all surrounding areas.
– Clean external appliance surfaces with a damp cloth or sponge.
Caution - Precaution
Only clean with food safe detergents. Never use corrosive or flammable cleaning
products or products that contain substances harmful to human health.
For long periods of disuse, after cleaning and turning off appliance power (or unplug-
ging the power cord), adequately cover it to keep it clean.
TROUBLESHOOTING
The purpose of the following information is to help the operator to identify and correct
any anomalies or malfunctions that may occur during use.
If one of the faults listed in the table occurs, inform the manufacture to actively contrib-
ute in developing new solutions and improving construction techniques.
- 13 -