▶ Remove the battery/batteries.
▶ Never transport batteries loose and unprotected. During transport, batteries should be protected from
excessive shock and vibration and isolated from any conductive materials or other batteries that may
come in contact with the terminals and cause a short circuit. Comply with the locally applicable
regulations for transporting batteries.
▶ Do not send batteries through the mail. Consult your shipper for instructions on how to ship undamaged
batteries.
▶ Prior to each use and before and after prolonged transport, check the product and the batteries for
damage.
Storage
WARNING
Accidental damage caused by defective or leaking batteries !
▶ Always store your products with the batteries removed!
▶ Store the product and the batteries in a cool and dry place. Comply with the temperature limits stated in
the technical data.
▶ Do not store batteries on the charger. Always remove the battery from the charger when the charging
operation has completed.
▶ Never leave batteries in direct sunlight, on sources of heat, or behind glass.
▶ Store the product and batteries where they cannot be accessed by children or unauthorized persons.
▶ Prior to each use and before and after prolonged storage, check the product and the batteries for
damage.
8.1
Transport and storage of dispensers
▶ For transporting and storing the tool, set the dispensing mode selector switch to
9
Troubleshooting
If a problem occurs, always observe the charge-status and fault indicator of the battery. See the section
headed Status indicators of the Li­ion battery.
If the trouble you are experiencing is not listed in this table or you are unable to rectify the problem by
yourself, contact Hilti Service.
Trouble or fault
Product does not work.
Product prematurely aborts
dispensing operation
The battery does not engage
with an audible click.
The product or battery gets
very hot.
*2293681*
Possible cause
The battery is not fully inserted.
Battery is discharged.
Dispensing mode selector switch
set to
The overload cut-out is activated;
mortar in the mixing nozzle has
hardened
The overload cut-out is activated;
The dispensing pressure required
is too high for the product.
Foil pack empty
The retaining lug on the battery is
dirty.
The product is overloaded (appli-
cation limits exceeded).
2293681
.
Action to be taken
▶ Push the battery in until it
engages with an audible click.
▶ Change the battery.
▶ Select the desired dispensing
volume.
▶ Replace the static mixer (mixing
nozzle).
▶ Increase the foil pack tempera-
ture.
▶ Replace the empty foil pack.
▶ Clean the retaining lug and push
the battery in until it engages.
If the problem persists, consult
Hilti Service.
▶ Pay attention to the power
and performance rating of the
product before using it, i.e
check its suitability for the job
on hand. See "Technical data"
section.
English
27