1-1/2 HP Models
1. Press the black voltage change
device down onto the voltage
terminals.
2. Set the black voltage change
device so that the white arrow
points directly to the desired
voltage.
3. Reassemble the terminal box
cover.
2HP Models
230 V
Wiring the Pump
1. Employ an electrician to do the wiring.
2. Provide a separate circuit from the distribution panel to the pump unit, properly protected with a
fuse or circuit breaker.
3. Install a proper fused disconnect switch in the line.
• Use the correct gauge of cable to carry the load.
IMPORTANT: Undersized wire between the motor and the power source will adversely limit the
starting and load carrying abilities of the motor.
4. Wire the motor according to the motor nameplate to achieve clockwise rotation when viewed from
the motor end.
• Very long leads will require a larger cable.
• If needed, remove motor end compartment for viewing.
5. Make sure the insulated green or bare ground wire is securely connected to the green ground termi-
nal screw on the motor terminal board.
115 V
Brown
White
230
115
INSTALLATION
Electrical Connections
230 V
Brown
White
230
115
5