FIXTURE PACKING LIST
Description
A LED Light Fixture...............................................................................1
B Knuckle
B Knuckle .............................................................................................1
C Mounting Plate .................................................................................1
D D Yoke
Yoke .................................................................................................1
E 1/2" 8-32 Mounting screws*
1/2" 8-32 Mounting screws* .............................................................2
F Wire Nuts*
Wire Nuts* .........................................................................................3
*Contained in parts packs
Remove fixture components and parts pack. Check to ensure all parts
are included. Note: Account for small parts and destroy packing material,
as these may be hazardous to children.
Features
switchable photocontrol
color temperature
adjustable lumens
NO, 2,500* only
Knuckle
Knuckle installed & Mounting Plate included
Yoke
not provided
sold separately
*Factory setting
CHOOSE SETTINGS (OPTIONAL)
To change settings, use a 3/16" Allen wrench to remove the switch cover
on the side of the fixture See Figure C. Choose your settings and replace
switch cover. Tighten to min. 1.5ft-lbs (2Nm) to max. 1.8ft-lbs (2.5Nm).
FIXTURE INSTALLATION
For installation to properly installed and grounded UL listed recessed or
surface mounted weatherproof junction box.
Turn OFF Power at circuit breaker box.
CAUTION: Do not rely on wall switch alone to turn off power.
KNUCKLE MOUNT
Thread Mounting Plate (C) onto Knuckle (B) and tighten locknut to
secure or thread knuckle into a 1/2" NPS hole in a compatible mounting
apparatus. Note: Seal arm thread using Teflon tape or silicone sealant.
Refer to wiring instructions for power connection.
Make power connection, see wiring instructions
Use mounting screws (E) to secure Mounting plate to junction box.
To adjust the tilt angle of the fixture, loosen the 1/4-20 Socket Cap Screw
in the Knuckle with a 3/16" Allen wrench, rotate fixture to the desired
angle and re-tighten screw to min. 2.2ft-lbs(3Nm) to max. 2.5ft-lbs
(3.5Nm).
ESXF1 P0
ESXF1 ALO
ESXF2 ALO
ON*/OFF
3000K/4000K*/5000K
High 5,000*
High 7,500*
Med 3,000
Med 5,500
Low 1,500
Low 3,500
Yoke accessory included
photocontrol switch
color temperature switch
lumen level switch
8
7

INSTALLATION INSTRUCTIONS

D
Figure A
Quantity
C
C) Mounting Plate
F) Wire Nuts
B
YOKE MOUNT
If Yoke mount is desired, remove Knuckle and install Yoke.
To install Yoke mount
A
Remove Knuckle (B) from Fixture using 3/16" Allen wrench to remove
two 1/2" 1/4-20 Socket Cap Screws and pull Knuckle gently off cord.
Thread cord through center hole in upper section of Yoke (D).
8
7
Secure Yoke to housing with Socket Cap Screws removed earlier.
Tighten to min. 2.2ft-lbs (3Nm) to max. 2.5ft-lbs (3.5Nm)
Mount fixture to the desired bracketry with 3/8" bolts, lock washer, and nut
(not provided). See Figure B for template of yoke bracket hole pattern.
To adjust the tilt angle of the fixture, use 3/16" Allen wrench to loosen
the 5/8" 1/4-20" Socket Cap screws on both sides of the yoke. While
holding weight of fixture, use a 9/64" Allen wrench to remove 3/8" #8-32
Socket Cap set screw, adjust to desired angle and reinstall set screw in
appropriate matching hole. Re-tighten screws to min. 2.2ft-lbs (3Nm) to
max. 2.5ft-lbs (3.5Nm) to secure. See Figure C.
1.260" [32]
Ø0.437" [Ø11.1]
3PLACES
Figure B
CAUTION: WIRING
Make sure power is turned off.
Use wire nut to connect the bare copper or green house supply
ground wire to the green fixture ground wire. Note: If house wiring
does not include a ground wire, consult your local electrical code for
approved grounding methods.
For proper connection, place wire nut over wires
Use wire nut to connect the white fixture wire to the white (neutral)
house supply wire.
Use wire nut to connect the back fixture wire to the black house
supply wire.
Turn on electricity at fuse or circuit breaker box and verify success of
installation. Note: If photosensor is in ON postion, cover photosensor
window to block daylight from entering sensor and allow lights to activate
during daytime.
page 3
6
5
B) Knuckle
E) Mounting Screws
6
5
3.346" [85]
1.750" [44.5]
0.875" [22.2]
0.098" [2.5 ]
BRACKET THICKNESS
Photosensor
Switch cover
Figure C
Set Screw
Socket Cap Screw
and twist clockwise until tight.
4
3
2
A) Light Fixture
PROPRIETARY AND CONFIDENTIAL
THIRD ANGLE PROJE
THIS PRINT IS THE
CONFIDENTIAL PROPERTY OF
ACUITY BRANDS AND IS
LOANED SUBJECT TO RETURN
UPON DEMAND AND UPON
EXPRESS CONDITION THAT IT
WILL NOT BE DISCLOSED TO
ANY THIRD PARTY WITHOUT THE
PRIOR WRITTEN PERMISSION OF
ACUITY BRANDS OR USED
MATERIAL
DIRECTLY OR INDIRECTLY IN
ANY WAY DETRIMENTAL TO THE
FINISH
INTEREST OF ACUITY BRANDS
DO NOT SCALE DR
4
3
2

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Esxf2 alo sww2 ky ddb

Tabla de contenido