The user is liable for improper or non-in
tended use.
3.1
Routing tools
Type of feed
MAN (manual feed).
Speed
The maximum speed specified on the tool must
not be exceeded and the speed range must be
adhered to.
Materials
Wood, plastics. Observe the material informa
tion on the packaging.
Only qualified and experienced persons who are
familiar with the tools are permitted to use
them.
4
Technical data
Edge router
Power
Speed (no-load)
Max. routing diameter
Connection dia. d/e
Weight as per EPTA procedure
01:2014:
4.1
Routing tools
See imprint on the routing tool.
Cutters have been produced in compliance with
EN 847-1:2017.
5
Parts of the device
[1-1]
Extraction adapter angle adapter
[1-2]
Extractor connector
[1-3]
Guard
[1-4]
Guard fixture rotary knob
[1-5]
Guard fixture threaded hole
[1-6]
Adjusting ring routing depth
[1-7]
Locking slide routing depth
[1-8]
Gripping surface
[1-9]
Plug-it connection
[1-10]
On/off switch
[1-11]
Spindle stop locking button
[1-12]
Guide table
The specified illustrations appear at the begin
ning of the Operating Instructions.
6
Unauthorised voltage or frequency.
Risk of accidents
► The mains voltage and the frequency of the
power source must correspond to the
specifications on the name plate.
► In North America, only Festool machines
with the voltage specifications 120 V / 60 Hz
may be used.
Heating of the plug it connection if bayonet
fitting is not completely locked
Risk of burns
OFK 500 Q
► Before switching on the power tool, make
450 W
sure that the bayonet fitting at the mains
28,000 rpm
cable is closed fully and locked.
27 mm
► Connect and disconnect the mains power
cable [2].
27 mm
6.1
1.6 kg
The switch [1-10] serves as an on/off switch (I =
ON, 0 = OFF).
7
Risk of injury, electric shock
► Always disconnect the mains plug from the
socket before performing any work on the
machine.
7.1
The built-in restart protection prevents the
power tool from starting up again automatically
if the power is disconnected when the on/off
switch is pressed. In this case, the power tool
must be switched off and then switched back on
again.
Due to the built-in restart protection, the power
tool cannot be switched on and off via an exter
nal switch module.
7.2
► Secure guard [1-3] with the rotary
knob [1-4] to the threaded hole [1-5] of the
guide table.
Commissioning
WARNING
CAUTION
Switching on/off
Settings
WARNING
Restart protection
Fitting the guard
English
15