Descargar Imprimir esta página

Change Master Code - xpr VKP99 Manual Del Usuario

Publicidad

PROGRAMMING FLOWCHART
Assign a
User Code
Press (0)
+
Memory position from 01 to 99
Proximity
Keypad
Reader
Reader
Enter new code
Present Card/Tag
before the Reader*
Notes
Memory Position for User Code is always 2 digits
*no need to validate with A
Assign Examples
Ex.1: To assign User Code "12345" at Memory Position "5" and Relay (2A) in Latch Mode assuming Master code = 000
Press 000B + 0 + 05 + 12345 + A + 3 + 05 + 1 + A + 1 + 00 + A + B.
Ex.2: To assign User Code "6789" at Memory Position "6" and Transistor that activates for 5 seconds assuming Master code = 000
Press 000B + 0 + 06 + 6789 + A + 3 + 06 + 2 + A + 2 + 05 + A + B.
See: Assign a User code
above
Enter "Master Code" OR "000" (if first time use)
1 small beep + 1 long beep + Yellow LED is 'ON'
Change
Assign Output
Master Code
Press (3)
Press (0)
+
Memory position from
Memory
(01 to 99)
position (00)
Press (1) for Relay
Press (2) for Transistor
Press (12) for both
(1 to 8 digits)
Press B (Yellow LED is 'OFF')
See: Assign Output
above
www.xprgroup.com
Start
Validate by pressing (B)
Multiple small beeps
NO
Validation OK?
Yellow Led blinks rapidly
YES
Set Output Timer
Pulsed Mode (01 to 99 sec):
+
Relay (2A):
Press (1) + (from 01 to 99)
+
Transistor:
Pres (2) + (from 01 to 99)
OR
OR
Latch Mode (ON/OFF):
OR
Press (1) or (2) + (00)
Press A to validate
NO
Validation OK?
YES
Quit
NO
programming
YES
End
See: Output Timer
above
+
Delete Single
Delete All Codes
Code
Press (9)
+
Memory position
from (01 to 99)
Press (8)
+
(99)
5

Publicidad