Draining:
With the menu Draining you can separately
empty stages 1, 2 and 3.
Draining a stage:
Use the buttons
•
desired stage.
Confirm with button
•
indicates "on" behind the stage. The stage
is drained.
Use the button
•
process. If you fail to do so, the control sys-
tem will empty the stages until the level has
dropped below the minimum fill level.
Function test:
If you call the menu function test, the facility
switches from automatic mode to manual
mode. The green LED blinks and all consumers
are switched off!
In the menu function test, the different functions
of the facility can be tested.
Testing a function:
Use the buttons
•
function you want to test.
Confirm with button
•
cates "on" behind the selected function.
050608
or
to select the
. The display now
to abort the draining
or
to select the
. The display indi-
Operating instructions AquaCycle 900
Activating the filter backflushing:
Press the button
•
cleaning is started immediately.
Testing the pumps:
If you select the pump stage 1 or pump stage 2,
the settling phase is started initially. To abort
the settling phase, press
then start immediately.
Testing the aeration:
If you select the aeration, time T_airoff will first
expire, then the aeration will be activated with
the time T_airon. To skip the time T_airoff,
press
. Aeration will then start immediately.
Testing the sediment extraction function:
The test requires you to switch on the pumps
Pump_sludge 1 or 2 for the set time.
. Automatic filter
. Recirculation will
EN15