Description Of Facility Components, Maintenance Work; Control System - Hansgrohe Pontos AquaCycle 900 Instrucciones De Servicio

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Description of facility components, maintenance work

Control system

The slots for the different consumers are lo-
cated in the bottom part of the control board.
The connections from C00 to C14 are arranged
from the left to the right. You can gather the slot
assignment from the tables below. All cables
are provided with a lug on which the respective
connection is specified. A fuse is located on the
far left of the printed circuit board (200 mA /
slow). In case of a defect, replace this fuse
against the spare fuse included in the delivery.
The spare fuse is located on the inside of the
service door.
Overview of slot assignment:
Slot
C00
C01
C02
C03
C04
C05
C06
C07
C08
C09
C10
C11
C12
C13
C14
Sensor connections:
The sensors are connected on the top right of
the printed circuit board. The connections are
arranged from the right to the left, stage 1
(=S01) on the far right, S02 stage 2 and S03
stage 3.
EN20
Designation
Mains supply
Pressure pump
Reserve
Reserve
Valve filter backflus-
hing
Valve backfeed
Rain water pump
Air pump 1
Air pump 2
Sludge pump stage 1
Sludge pump stage 2
Pumping sys-
tem/shower
Submersible pump
stage 1
Submersible pump
stage 2
UV lamp
Operating instructions AquaCycle 900
Slot
S01
S02
S03
Connection between I/O control board and
display module:
CPU 01 I/O printed
circuit board
CPU 02 I/O printed
circuit board
Pin assignment level sensors:
Colour
Function
Brown
Reference
Green
Maximum
level
White
Minimum level
Connection level sensors
Checking the tank sensors:
The sensor check is here depicted for one of
the three stages. Proceed in the same manner
for the other stages.
Checking the "maximum fill level":
Use a wire to bridge the middle sensor (max. fill
level) with the right hand sensor (reference) at
the connection of the sensors (viewed from the
front).
The menu Status display fill levels must depict
a "1" for maximum level.
Designation
Sensor system stage
1
Sensor system stage
2
Sensor system stage
3
Display module volt-
age supply 12 V
Display module com-
munication interface
(TAE-type cable)
Arrangement
right
centre
left
050608

Hide quick links:

Publicidad

Tabla de contenido
loading

Tabla de contenido