DUCTING TO HVAC SYSTEMS (Closet Installations)

9
WARNING!
WHEN INSTALLING THE DEHUMIDIFIER AS PART OF A COMBUSTION TYPE HVAC SYSTEM (GAS, OIL, PROPANE,
ETC.), FOLLOW ALL LOCAL AND NATIONAL BUILDING AND SAFETY CODES.

1. Recommended Closet Installation

Due to space limitations, a closet installation may require additional considerations. Locate the dehumidifier under
or next to the HVAC system as space allows. A passive vent or louver door is required to allow air to be pulled in
from the living space.
No inlet duct is required. Air is pulled through the passive vent or louver door from the living space.
Install an insulated duct from outside to the 6" collar of the Ultra Series Dehumidifier to provide outdoor air
ventilation (optional).
Control should be located remotely from the dehumidifier and placed in a central location.
Where outlet space is restricted, the outlet duct collar is optional or vertical flow through may be preferred.
Central Return to HVAC Supply
Duct the supply of the Ultra Series
Dehumidifier to the supply of the
existing HVAC system with a backdraft
damper.
16
Santa Fe ULTRA98/120 Installation & Operation Instructions
HVAC
Return
Optional Outdoor
Ultra Series
Air Intake
Return
HVAC
Supply
Backdraft
Damper
Santa-Fe-Products.com | 800.533.7533
Ultra Series
Supply
Motorized
Damper