ELECTRICAL REQUIREMENTS
6
The Santa Fe Ultra98/120 plugs into a common grounded 115VAC outlet. Locate the dehumidifier in an area
where the unit's 9 ft. cord can easily reach a 115 VAC electrical outlet with a minimum of 15 Amp circuit capacity.
If used in an area that may become wet, a GFCI protected circuit is recommended. Consult local electrical codes
for any further information.
Santa Fe offers a variety of control devices for use with the Santa Fe Ultra98/120. The controls are to be located
remotely from the dehumidifier and placed in the space to be conditioned. Low voltage (24 Volt) controls can be used
with the Santa Fe Ultra98/120 and MUST be connected with low voltage (18-22 gauge) thermostat wire.
WARNING!
THE REMOTE CONTROLS OF THE SANTA FE ULTRA98/120 ARE POWERED BY A LOW VOLTAGE CIRCUIT (24VAC)
AND MUST NEVER CONTACT OR BE CONNECTED TO A HIGH VOLTAGE CIRCUIT.
CAUTION!
DO NOT ALLOW THE 24V TERMINAL TO CONTACT THE COM/DMPR TERMINALS ON THE
SANTA FE ULTRA98/120 OR DAMAGE TO THE TRANSFORMER WILL RESULT.
CAUTION!
SOME OF THE SCREWS TERMINALS ON THE SANTA FE ULTRA98/120 MAY NOT BE USED WITH
CERTAIN CONTROLS AND SHOULD BE LEFT UNCONNECTED.
1. Electrical Precautions
•
Do not install the control where it may not accurately sense the relative humidity such as near HVAC
supply registers, near exterior doors, on an outside wall, near a window, or near a water source.
•
The screw terminals on the Santa Fe Ultra98/120 and the control are labeled to prevent confusion.
•
Be sure to consult the electrical schematic in the CONTROLS Section (pages 20-21) of this manual or
inside the access panel of the Santa Fe Ultra98/120 before making control connections.