The following table shows the electrical connections in Fig. 12:
Terminals
Function
L-N-GND
Supply
+ BATT -
Batteries
M0T1
Motor 1
M0T2
Motor 2
BLINK
Flashing light
LOCK
Electric lock
AUX1
AUX 1 auxiliary output
+ 24V -
Output 24Vdc
ENC1
Encoder MOT1
BAR
Sensitive edge
ENC2
Encoder MOT2
PHOT OP
Photocell OPEN
PHOT CL
Photocell CLOSE
STOP
STOP
OPEN
OPENED
CLOSE
CLOSED
PED
PEDESTRIAN
P.P.
Step-by-Step
COM
Common Inputs
AUX2
AUX 2 auxiliary output
A
N
T
-
Antenna
SHIELD
EXP1
Extension 1
EXP2
Extension 2
1) Disconnect power supply.
2) Manually release the gates, bring them to approx. half the stroke and lock them again.
3) Restore the power supply.
4) Give a step by step command using the button connected to the input of the PP, remote control or button <->.
5) The gates must move in opening.
If this is not the case, simply invert the motor running wires, rotating the connector of MOT1 on SAM.E24 180° degrees and
inverting the MOT2 wires for the SAM.24 motor.
6) Using MINV logic, select the motor which must start to move first in opening, see Fig.14.
7) Execute an autoreset procedure (see AUTOSET menu).
The default setting includes installation of the motor with the control panel (SAM.E24) on the right gate (as in the Fig.13) with the
right gate that starts first (MINV:OFF logic)
28
CP.SAM CONTROL PANEL

ELECTRICAL CONNECTIONS

Description
Mains input 115-230Vac 50-60Hz
Input for connection of the back-up batteries (accessory)
Quick connector for connection of 24 Vdc MOT1 motor (SAM.E24).
Connector for connection of 24 Vdc MOT2 motor (SAM.24).
24Vdc flashing connection 4W max.
Electric lock connection.
Output with configurable N.O. contact from working parameter AUX1. Max load 500
mA.
Power supply output accessories 24Vdc/0.5A max.
ATTENTION!! With ESA:ON logic, during the Stand-by phase, the power supply of
the accessories is interrupted. See ESA Logic
Quick connector for connection of MOT1 encoder (SAM.E24).
Sensitive bar contact input, a resistor is pre-installed on the terminals of 8,2 KOhm.
Resistive bar 8K2: connect the bar to the terminals eliminating the pre-installed resis-
tance as indicated in Figure 12.
Mechanical bar: connect the bar in series to the resistance as indicated in Figure 12.
The intervention of the bar stops movement of the gate and inverts for approx. 3s.
Connector for connection of the MOT2 encoder (SAM.24).
Use a 3x0.5mm
2
long cable maximum 10m.
Photocell input enabled in OPENING and CLOSURE (N.C. contact).
Photocell input enabled in CLOSURE (N.C. contact).
STOP button input (N.C. contact)
OPEN button input (N.O. contact). You can connect a timer for opening in time slots.
CLOSE button input (N.O. contact).
Pedestrian button input (N.O. contact), opening command of motor 1, see TPED pa-
rameter.
Step-by-Step button input (N.O. contact) .
Common for the inputs for control and photocells and STOP
Output with configurable N.O. contact from working parameter AUX1. Max load 500
mA.
Integrated radio-receiver board antenna connection
(FRONT: Signal - SHIELD: Screen)
Expansion connector for serial KNX or pro.UP
Expansion connector for serial pro.UP
CONNECTIONS CHECK