ATTENTION!!!
It means the fire has gone out automatically during
the operation, when the exhaust gas temperature is
lower than 40-45 degree.
Such as:
1. There is no fuel in the hopper.
2. Auger motor is broken and stops feeding the
fuel.
It means Igniter failure at the beginning.
Such as:
1. There is clinker in fire pot.
2. The fire pot has not been put in correctly.
3. The switch that is located beside the combustion
fan to test the exhaust gas temperature sensor is
broken.
4. The igniter is broken
It means there is an earthquake during the opera-
tion time or the stove has been tilted.
Only for the Japanese version.
Problem with the temperature sensor.
Unplugged, broken or water temperature is too
high (This function is only for the pellet stove with
hot water).
It means that there are some problems with
vacuum. Such as: door has not been closed
properly; Combustion fan's speed cannot
accelerate; There is some leakage in the stove or
the exhaust pipe is blocked.
It means that the high temperature sensor, which
is located below the hopper, has some problem.
Such as: 1. the switch is broken,
2. The temperature is too high so that the stove
does not run properly.
EN
25
Version: 11
08.11.2022