4 Optional remote air sensor cable
5 Seawater outlet hose
6 Overboard discharge
7 Seawater inlet hose
8 Seawater scoop thru-hull inlet
6 Specifications
This section contains specification data for the air conditioning unit.
Table 1: Minimum duct and grille sizes per BTU capacity
Minimum duct diame-
ter
Minimum duct area
Minimum return air
grille
Minimum supply air
grille
Table 2: Operating water temperature and pressure
Minimum operating water temperature
Maximum operating water temperature
Minimum operating water pressure
Maximum operating water pressure
Note The unit can operate outside these conditions with reduced capacity.

7 Pre-installation

NOTICE!
The Turbo and Voyager self-contained condensate base pans are equipped with vibration isolators installed in the bot-
tom of the pan. These isolators are designed to dampen the vibration caused by the operating air conditioner from
transferring into the mounted surface. Care must be taken when moving the air conditioner across mounting surfaces as
the isolators can be damaged.
NOTICE!
The air conditioner must be mounted to a low, flat, level surface, like in the bottom of a locker, under a bunk or dinette
seat, or in a similar location.
This section explains how to prepare the air conditioner for installation.
7.1
Determining the installation location
Voyager placement relative to airflow -
6
3.5 k BTU
6 k BTU
8 k BTU
3.0 in
4.0 in
5.0 in
(76.00 mm)
(102.00 mm)
(127.00 mm)
2.6 in²
5.0 in²
7.7 in²
(17.00 cm²)
(32.00 cm²)
(50.00 cm²)
25.3 in²
25.3 in²
31.5 in²
(163.00 cm²)
(163.00 cm²)
(203.00 cm²)
4.6 in²
12.6 in²
18.9 in²
(30.00 cm²)
(81.00 cm²)
(122.00 cm²)
12 Condensate drain hose barb
13 Mounting bracket
14 Air conditioner
15 Return air grille and filter
16 Insulated flexible ducting
10 k BTU
12 k BTU
16 k BTU
6.0 in
6.0 in
7.0 in
(152.00 mm)
(152.00 mm)
(178.00 mm)
11.2 in²
11.2 in²
15.2 in²
(72.00 cm²)
(72.00 cm²)
(98.00 cm²)
39.4 in²
51.1 in²
78.7 in²
(254.00 cm²)
(330.00 cm²)
(508.00 cm²)
23.6 in²
27.6 in²
31.5 in²
(152.00 cm²)
(178.00 cm²)
(203.00 cm²)
39.2 °F (4.00 °C)
80.6 °F (27.00 °C)
4.2 psi (29.00 kPa)
6.00 psi (41.4 kPa)
18 k BTU
27 k BTU
7.0 in
8.0 in
(178.00 mm)
(203.00 mm)
15.2 in²
19.8 in²
(98.00 cm²)
(128.00 cm²)
78.7 in²
94.5 in²
(508.00 cm²)
(610.00 cm²)
39.4 in²
55.2 in²
(254.00 cm²)
(356.00 cm²)
 