EN
Gas Container
•
The LP-gas cylinders used must be constructed and marked in accordance with the specifications for LP-gas cylinders of the U.S>
Department of Transportation or Transport Canada, the standard for cylinders, spheres, and tubes for the transportation of dangerous
goods, CAN/CSA B339.
•
Gas is supplied to the unit via a hose and a regulator supplied with the unit. The hose and regulator is connected to a CGA No. 600 type
thread propane cylinder not exceeding 1lb (See Fig.2). This appliance can also use a 20 lb propane cylinder with an alternate hose and
regulator assembly (not included). Please also refer to Section 2 for use of a 20 lb propane cylinder.
•
IT COULD BE HAZARDOUS TO ATTEMPT TO FIT OTHER TYPES OF GAS CARTRIDGES.
•
This appliance must only be used with an approved hose and regulator.
•
Only to be used with a gas cylinder that does not exceed 20" in height (not including the regulator) and 16" in width.
•
Ensure that the gas container is fitted or changed in a well-ventilated location, preferably outdoors, away from any sources of ignition such
as naked flames, pilots, electric fires and away from other people.
•
Keep gas containers away from heat and flame. Do not place on a stove or any other hot surface.
•
Refillable containers are to be used only in the upright position so as to ensure proper fuel withdrawal. Failure to adhere to this may cause
liquid discharge from the gas container resulting in a dangerous operating conditions.
•
Do not try to remove the gas container whilst the appliance is in operation.
•
The gas container must be disconnected from the appliance after use or when in storage.
Light back
•
In the event of light back (where the flame burns back and ignites inside the burner or venturi housing), immediately turn off the gas supply
by firstly closing the control valve on the gas cylinder and then the appliance valve. After the flame is extinguished, remove the regulator
and check the condition of the seal; replace the seal if in doubt. Re-light the appliance.
•
Should the flame persistently light back, return the product to your authorized repair agent.
Leaks
•
If there is a gas leak on your appliance (smell of gas), immediately turn off the gas supply by turning the control knob clockwise to the "OFF"
position and take it into a flame free location where the gas leak may be detected and stopped. If you wish to check for gas leaks on your
appliance, do it outside. Do not try to detect gas leaks using a flame; use soapy water.
How to check the appliance is connected to the gas supply in a sound fashion
•
It is important that all gas connections have been correctly connected to prevent any gas leaks.
•
The correct way is to smear the joint, i.e. where the gas container connects to the appliance, with soapy water. Turn the appliance control knob
slightly anti-clockwise to turn the gas on. If bubbles form, then there is a gas leak. Immediately turn the gas off and disconnect the gas supply
from the appliance. Check that all the connections are properly fitted. Check that the seal is in place and in good condition before connecting
the gas supply. Re-check with soapy water after refitting the gas supply.
•
If a gas leak persists, return the product to your local dealer for inspection/repair.
•
ONLY USE IN WELL VENTILATED AREAS.
•
CARBON MONOXIDE HAZARD - USING THIS APPLIANCE IN AN ENCLOSED SPACE MAY CAUSE DEATH. DO NOT USE IN CARAVANS,
TENTS, MARINE CRAFT, CARS, MOBILE HOMES OR SIMILAR LOCATIONS.
•
This appliance shall only be used in an above ground open air situation with natural ventilation, without stagnant areas, where gas leakage
and products of combustion are rapidly by wind and natural convection.
•
Any enclosure in which the appliance is used shall comply with one of the following:
•
An enclosure with walls on all sides, but with no overhead cover.
•
Within a partial enclosure that includes an overhead cover and no more than two walls.
•
Within a partial enclosure that includes an overhead cover and more than two walls, the following shall apply:
•
•
•
Country of use
Appliance Categories
Allowable gases and
operating pressure
Nominal usage
Gross nom. heat input
Jet number
At least 25% of the total wall area is completely open.
30% or more in total of the remaining wall side, back and front wall areas is open and unrestricted.
In the case of balconies, 20% or more of the total wall area shall remain open and unrestricted.
Gas supply sources (not supplied):
a)
A refillable gas container not exceeding 20 lb and complying with local regulation in force.
b)
a CGA No. 600 type thread propane cylinder not exceeding 2.2 lb
US & Canada
LPG
2.74 kPa
196g/hour
9220 BTU
80