X-Boost Feature - EcoFlow POWER HUB Manual Del Usuario

Ocultar thumbs Ver también para POWER HUB:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 83
Vehicle Alternator System
12V
24V
48V
1. Vehicle Alternator Charging will only operate when vehicle is on move. If idle
charging is needed, user can toggle the idle charging button via EcoFlow APP.
2. Connect ALT IN1 port as a priority for vehicle alternator charging.
Priority of multiple charging
Power Hub supports multiple charging input simultaneously, and the charging
priorities are: solar charging, AC charging, vehicle alternator charging and EcoFlow
smart generator charging.
The total charging current at the battery port of the Power Hub is limited to 100A.
When the charging input power is greater than the power required by the battery,
the charging input with lower priority will reduce charging current smoothly or even
stop charging.

X-Boost Feature

With EcoFlow X-Boost technology, this product can power a 5200 W Max device (for
heating appliances only) while the rated output power remains 3600 W, avoiding
operation failure due to overload protection.
1. The X-Boost feature is unavailable when AC Output is in bypass mode.
2. The X-Boost feature is not suitable for all appliances. The X-Boost feature is
only suitable for heating appliances. It is not suitable for some appliances with
voltage protection, such as precision instruments.
Vehicle Alternator Voltage
<13V
<26V
<52V
Alternator charging will
stop to protect vehicle
starter battery from over-
discharging
EN
11

Publicidad

Tabla de contenido
loading

Tabla de contenido