i.safe MOBILE IS330.1 Manual Del Usuario página 4

Ocultar thumbs Ver también para IS330.1:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 12
EX-RELEVANT SAFETY REGULATIONS FOR NORTH AMERICA
Conditions of Acceptability:
The battery may be charged outside explosion hazardous areas only using approved external
adapter model ICP12-050-2000B with output rated 5Vdc, 2A or other external approved AC/
DC adapter which also complies with the requirements of LPS and has output rated 5Vdc, 2A .
The battery may be replaced with an identical one outside of the explosion hazardous areas only .
To ensure the IP64 protection, it has to be ensured that all gaskets are present and functional .
There must be no gap between the two halves of housing and between the battery cover and
housing .
The USB interface (type C) located at the left side is for data transmission and it is used in non
hazardous areas . It is not permitted to open the USB interface cover in hazardous locations .
The ISM interface of the device located at the right side can be used within hazardous areas
with approved headsets, Remote Speaker Microphones(RSM) and add-ons .
For the ISM interface-connection the intrinsically safe approved accessories must comply with
entity parameters according to document 1029AD04 i .e . Headset IS-HS1.1 is approved to be
used on ISM interface . If the ISM interface is not used, it must be securely closed by the cover
provided for this purpose .
The device must be protected against excessive UV light emission and high electrostatic
processes .
The device may only be charged at temperatures between +5°C . . . +35°C .
INFORMATION CONCERNING SAR CERTIFICATION
(SPECIFIC ABSORBATION RATE)
Maximum SAR values for this model and the conditions under which these were determined:
SAR (head)
SAR (body - worn)
This device was tested for typical body-worn operations with the back of the handset kept
5 mm from the body .
NB WARNING
CAUTION
Use careful with the earphone maybe possible excessive sound pressure from
earphones and headphones can cause hearing loss .
CAUTION: RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE .
DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS .
Operation temperature: -20°C ...+60°C (EN/IEC 60079-0)/ -10°C ...+50°C (EN/IEC 62368-1) .
The device shall only be connected via the i.safe PROTECTOR 2.0 USB cable or another
accessory authorised by i.safe MOBILE GmbH .
AC Adapter:
Approved external adapter model ICP12-050-2000B (Input: AC100-240V 50/60Hz 0 .3A;
Output: 5VDC, 2A) or other approved external AC/DC adapter which complies with the
requirements of LPS (Limited Power Source) and has output rated 5VDC/2A .
Adapter shall be installed near the equipment and shall be easily accessible .
The plug is considered independent of the adapter .
4
0 .62 W/kg
0 .93 W/kg