14. Troubleshooting
Fault
Possible cause
The compressor does
Mains voltage is not available.
not start.
Mains voltage is too low.
Outside temperature is too low.
Motor is overheated.
The compressor starts but
The safety valve leaks.
there is no pressure.
The seals are damaged.
The drain screw for condensate leaks.
The compressor starts,
The hose connections have a leak.
pressure is shown on the
pressure gauge, but the
A quick coupling has a leak.
tools do not start.
Insufficient pressure set on the pressure regula-
tor.
10
GB/IE
Remedy
Check the cable, mains plug, fuse and socket.
Make sure that the extension cable is not too long. Use an
extension cable with large enough wires.
Never operate with an outside temperature of below +5
°C.
Allow the motor to cool down. If necessary, remedy the
cause of the overheating.
Contact your local service centre. Only allow qualified
personnel to carry out repairs.
Check the seals and have any damaged seals replaced by
a service centre.
Tighten the screw by hand. Check the seal on the screw
and replace if necessary.
Check the compressed air hose and tools and replace if
necessary.
Contact your local service centre. Only allow qualified
personnel to carry out repairs.
Increase the set pressure with the pressure regulator.