  • ESPAÑOL, página 110
DE
compressor and centrifugal fan run and stop in alternating order for 8 and
6 minutes, respectively.
EN
Ventilation
FR
15. The fan operates at the selected level, and the compressor is off. There is no
NL
option to select the temperature.
IT
Timer
16. The adjustable time ranges from 1 to 24 hours of operating time. Press the
ES
buttons + and - to set the desired time. You can adjust the operating time
PL
in increments of 1 hour. After approx. 5 seconds with no input, the display
returns to indicating the target temperature, the "h" indicator is lit, and
the previously set time is stored. If you press the Timer button again while
making the adjustment, the set time will not be stored.
Sleeping/Child Lock
17. This setting can only be adjusted in "Cooling" mode.
18. Press this button once with the appliance set to Cooling mode. The top
fan will then automatically run at low speed, and the target temperature
will first drop by 1°C after an hour and then by 2°C after two hours. The
appliance will automatically switch off after six hours.
19. Pressing and holding this button for at least 5 seconds will activate the
button, protecting the appliance from inadvertent operation. Another long
press of this button will deactivate the button lock again.
Oscillation
20. Press this button to activate oscillation. The top fins will now swing from left
to right and distribute the air evenly. To disable this function again, press
this button one more time.

MEMORY FUNCTION

1.
The appliance has a memory function. When the appliance is ready for
operation, but not switched on, the setting of its last operation (timer, etc.)
will remain. When you switch it on, the appliance will continue in the mode
selected last, unless the previous mode was automatic mode.