Ferroli EGEA 200 HT Manual De Uso, Instalación Y Mantenimiento página 115

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

EGEA
200 HT - 260 HT
Parameter Description
Use of the evaporator fan with the compres-
P58
sor off
Evaporator fan speed (EC) with compressor
P59
off
Temperature difference 1 of evaporation of
P60
the air for the calculation of the setpoint
Temperature difference 2 of evaporation of
P61
the air for the calculation of the setpoint
Temperature difference 3 of evaporation of
P62
the air for the calculation of the setpoint
Temperature difference 4 of evaporation of
P63
the air for the calculation of the setpoint
Temperature difference 5 of evaporation of
P64
the air for the calculation of the setpoint
Temperature difference 6 of evaporation of
P65
the air for the calculation of the setpoint
Band 2 evaporator temperature proportional
P66
regulation
Band 3 evaporator temperature proportional
P67
regulation
Band 4 evaporator temperature proportional
P68
regulation
Band 5 evaporator temperature proportional
P69
regulation
Band 6 evaporator temperature proportional
P70
regulation
EC evaporator fan speed reduction for silent
P71
mode
P72
EC fan speed regulator gain
(1) = NOT USABLE FOR THIS EQUIPMENT
Range
0 = OFF
1 = ON with manual speed
control
2 = ON with automatic speed
control
0÷100%
1÷25°C
1÷25°C
1÷25°C
1÷25°C
1÷25°C
1÷25°C
1÷20°C
1÷20°C
1÷20°C
1÷20°C
1÷20°C
0÷40%
1÷100
cod. 3541T590 - Rev. 05 - 12/2021
Default
0
40%
4°C
2°C
6°C
3°C
10°C
18°C
2°C
9°C
5°C
10°C
5°C
15%
5
Notes
Modifiable (1)
Modifiable (1)
Modifiable (1)
Modifiable (1)
Modifiable (1)
Modifiable (1)
Modifiable (1)
Modifiable (1)
Modifiable (1)
Modifiable (1)
Modifiable (1)
Modifiable (1)
Modifiable (1)
Modifiable (1)
Modifiable (1)
115
EN

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Egea 260 ht

Tabla de contenido