1.3 Automatic turn off
The device automatically turns off after 15 seconds of non-use. To turn it back on, turn the
rotary switch to any position (except OFF).
2. GENERAL SPECIFICATIONS
• Electrical protection class: CAT III 600 V
• Pollution degree: 2
• Calibration: Manual
• Operating altitude: < 2000 m
• Operating temperature / humidity: 0°C - 40°C (< 80 %RH)
• Storage temperature / humidity: -20 ° C - 60 ° C (<90% RH, Battery removed)
• Use: Only suitable for indoors
• Typical temperature coefficient: 0,1 x Accuracy 0 ° C (<18 ° C or> 28 ° C)
• Input voltage max. between the terminals and the ground: 600 V
• Protection fuse: FF : F1 500 mA/600 V - FF : F2 10 A/600 V
• Measuring frequency: Ca. 3-times / sec
• Display: LC-Screen 3,5 digits, Max value. : 1999.
• Indicator of measuring overflow: The digit «1» will be displayed in the screen
• Low battery indicator: If the battery voltage drops below the «normal operating voltage», the
symbol «
» appears on the display.
+
• Polarity indicator: The symbol «-» appears automatically to indicate a negative polarity.
• Power supply: Battery 1.5V×2, AAA R03P
• Dimensions / Mass: 155 (L) x 74 (W) x 40 (H) mm / approx. 155g
3. ELECTRICAL SPECIFICATIONS
Precision: ± (% of reading + number of digits) at a temperature between 18 and 28 ° C with a
relative humidity of <75%; Guarantee for a period of one year.
3.1 DC Voltage
MEASURING RANGE
200mV
2V
20V
200V
600V
Input impedance: 10MΩ.
Input voltage max.: 600 V
RESOLUTION
100μV
1mV
10mV
100mV
1V
or V~ rms. Range 200 mV : 250 V
ACCURACY
± (1.0 % the measured value + 2 digits)
± (1.2% the measured value + 2 digits)
or V~ rms.
or V~ rms
13