Storage And Transportation - D Devices D ENDO ROTATORY Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

.
Notes:
a) Only products that have been effectively cleaned and disinfected
are allowed to be sterilized;
b) Before using the sterilizer for sterilization, read the Instruction
Manual provided by the equipment manufacturer and follow the
instructions.
c) Do not use hot air sterilization and radiation sterilization as this
may result in damage to the product;
d) Please use the recommended sterilization procedures for sterili-
zation. It is not recommended to sterilize with other sterilization pro-
cedures such as ethylene oxide, formaldehyde and low temperature
plasma sterilization. The manufacturer assumes no responsibility
for the procedures that have not been recommended. If you use the
sterilization procedures that have not been recommended, please
adhere to related effective standards and verify the suitability and
effectiveness.
* Fractional pre-vacuum procedure = steam sterilization with
repetitive pre- vacuum.The procedure used here is to perform steam
sterilization through three pre-vacuums.
6.4.9 Storage
1. Store in a clean, dry, ventilated, non-corrosive atmosphere with a
relative humidity of 10% to 93%, an atmospheric pressure of 70KPa
to 106KPa, and a temperature of -20 °C to +55 °C;
2. After sterilization,the product should be packaged in a medical
sterilization bag or a clean sealing container, and stored in a special
storage cabinet. The storage time should not exceed 7 days. If it is
exceeded, it should be reprocessed before use.
Notes:
a) The storage environment should be clean and must be disinfected
regularly;
b) Product storage must be batched and marked and recorded.
6.4.10
Transportation
1. Prevent excessive shock and vibration during transportation, and
handle with care;
2. It should not be mixed with dangerous goods during transporta-
tion.
3. Avoid exposure to sun or rain or snow during transportation.

7 Storage and transportation

7.1 The equipment should be handled with care, away from the
26

Publicidad

Tabla de contenido
loading

Tabla de contenido