7 Technical data
Technical data
Input voltage, L1/N
Input frequency
Max. current consumption
Maximum current, L1 connection
Leakage current, mains filter
DC output voltage
Maximum continuous current, DC
outputs
Fuse, DC output
Protection class
Overvoltage category
Degree of contamination
Supply connection
Electrical connections
Operating temperature range
Max. relative humidity
Protection
Device operation
Dimensions
(H x W x D in mm)
Weight
Certifications
CE marking
Festo Didactic 8068435
1 x 230 V AC ±10%
50 ... 60 Hz
10 A
10 A
< 0.5 mA
24 V
2 A, not feedback-protected!
Resettable 2 A fuse
1, operation with protective earthing
II, operation in building installations
2, laboratory environment
Recessed plug per EN 60320, C14
Safety laboratory cables per EN 61010-031,
min. conductor cross-section: 1 sq. mm
5 ... 40° C / 100%
80%
IP 20 (not attached to the mounting frame)
Use only indoors, max. altitude: 2000 m above sea level
297 x 133 x 95
2.5 kg
Low-voltage directive
EMC directive
RoHS directive
23