• Be sure lift point is stable and that load is centered
on the jack saddle.
• Pump handle force must not exceed maximum
permitted for the jack model being used.
• Keep jack away from flames and heat. Do not weld
or modify jack.
• Do not overload the jack. Load must not exceed the
jack's rated capacity.
• Do not lift the load higher than necessary.
• Do not place objects under the load being lifted by the jack.
• Do not apply force to any object being lifted by the jack.
• Remove the pump handle from the handle socket
on jack when not in use. Use only the pump handle
supplied with the jack or an exact replacement of the
same specifications.
• Do not remove the jack oil fill/air release plug for any
reason unless jack is fully lowered.
• Never attempt to service, repair or adjust the jack
while it is supporting a load.
4.0 SPECIFICATIONS
Capacity
Model
US ton [kN]
GBJ002A
2.2
[19.6]
GBJ002LA
2.2 [19.6]
GBJ003A
3.3 [29.4]
GBJ005A
5.5 [49.1]
GBJ008A
8.8 [78.5]
GBJ010A
11.0 [98.1]
GBJ010SA
11.0 [98.1]
GBJ015A
16.5 [147.2]
GBJ020A
22.0 [196.2]
GBJ020SA
22.0 [196.2]
GBJ030A
33.1 [294.3]
GBJ050A
55.1 [490.5]
GBJ100
110.2 [981.0]
Max.
Min.
Stroke
Height
inch [mm]
inch [mm]
4.13 [105]
6.61 [168]
18.11 [460]
22.44 [570]
4.13 [105]
6.61 [168]
5.91 [150]
8.35 [212]
5.91 [150]
8.62 [219]
5.91 [150]
8.62 [219]
2.44 [62]
5.16 [131]
5.91 [150]
8.98 [228]
5.91 [150]
9.21 [234]
4.13 [105]
7.48 [190]
5.91 [150]
9.53 [242]
5.51 [140]
10.24 [260]
5.91 [150]
11.81 [300]
Failure to observe and comply with the following
precaution could result in minor or moderate
personal injury. Property damage could also occur.
• Immediately replace worn or damaged parts with
genuine Enerpac parts. Enerpac parts are designed to
fit properly and to withstand high loads. Non-Enerpac
parts may break or cause the product to malfunction.
• High force tool equipment must only be serviced by
a qualified technician. For repair service, contact the
Enerpac Authorized Service Center in your area .
3.0 CONFORMANCE TO NATIONAL AND
INTERNATIONAL STANDARDS
compatible to all EU and UK Requirements.
Copies of the EU Declaration as well as the UK Self-
Declaration are enclosed with each shipment.
Max. Pump
Max. Height
Handle Force
inch [mm]
lb [kgf]
13.31 [338]
88.2 [40]
40.55 [1030]
88.2 [40]
13.31 [338]
88.2 [40]
17.20 [437]
88.2 [40]
17.48 [444]
88.2 [40]
17.48 [444]
88.2 [40]
8.78 [223]
88.2 [40]
17.83 [453]
88.2 [40]
18.07 [459]
88.2 [40]
13.78 [350]
88.2 [40]
18.39 [467]
88.2 [40]
15.75 [400]
88.2 [40]
17.72 [450]
88.2 [40]
2
CAUTION
Enerpac declares that this product
has been tested and conforms to
applicable
standards
Ext. Screw
Net Weight
Height
lb [kg]
inch [mm]
2.56 [65]
7.9 [3.6]
N/A
22.7 [10.3]
2.56 [65]
8.1 [3.7]
2.95 [75]
9.9 [4.5]
2.95 [75]
13.6 [6.2]
2.95 [75]
14.1 [6.4]
1.18 [30]
11.0 [5.0]
2.95 [75]
19.4 [8.8]
2.95 [75]
23.3 [10.6]
2.17 [55]
20.9 [9.5]
2.95 [75]
34.2 [15.5]
N/A
59.4 [27.0]
N/A
191.8 [87.0]
and
is
Base Area
inch [mm]
2.95 x 4.59
[75 x 116.5]
2.95 x 4.59
[75 x 116.5]
2.95 x 4.59
[75 x 116.5]
2.95 x 4.92
[75 x 125]
3.54 x 5.67
[90 x 144]
3.54 x 5.67
[90 x 144]
3.54 x 5.67
[90 x 144]
4.33 x 6.48
[110 x
164.5]
4.72 x 6.79
[120 x 172.5]
4.72 x 6.79
[120 x 172.5]
5.67 x 7.72
[144 x 196]
6.50 x 8.43
[165 x 214]
11.65 x 13.11
[296 x 333]