Thermal power
Natural gas
(Family 2)
Electrical supply
Motor
Capacitor
Ignition transformer
Absorbed electrical power
(1) Reference conditions:
For gas family 3 (LPG) ask for separate kit.
COUNTRY
GAS CATEGORY
2.2 OVERALL DIMENSIONS
305
D4251
2.3 WORKING FIELD
1.6
1.4
1.2
1.0
0.8
0.6
0.4
0.2
0
40
D5256
40,000
20027965
(1)
42 – 116 kW
Net heat value: 8 – 12 kWh/Nm
Pressure: min. 16 mbar
Single phase, 230 V
230V / 0.7 A
4 F
Primary
0.13 kW
Temp. 20°C - Barometric pressure 1013 mbar – Altitude 0 m above sea level.
DE
AT
II 2ELL3B/P
II 2H3B/P
Burner
33
Combustion head extension, supplied separately.
(as EN 676)
50
60
70
50,000
60,000
-
36,000 – 100,000 kcal/h
-
max. 100 mbar
~
±
10%
50Hz
230V / 1.8 A
-
Secondary 8 kV / 30 mA
FR
II 2Er3P
110
346
170
61
80
90
70,000
80,000
2
GB
3
-
7,000 – 10,340 kcal/Nm
ES - GB - IE
LU
II 2H3P
II 2E3B/P
100
110
90,000
100,000
Thermal power
3
NL
II 2L3B/P
Flange
185
130
120
kW