Technical Data; Burner Equipment - Riello 40 F20 Instrucciones Para La Instalación, Uso Y Mantenimiento

Ocultar thumbs Ver también para 40 F20:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

TECHNICAL DATA

TYPE
Output - Thermal power
Fuel
Electrical supply
Motor
Capacitor
Ignition transformer
Pump
Absorbed electrical power
Burner with CE marking in conformity with EEC directives:
EMC 89/336/EEC, Low Voltage 73/23/EEC, Machines 98/37/EEC and Efficiency 92/42/EEC.
The burner meets protection level of IP 40, EN 60529.
9
4
3
1 – Return line
2 – Suction line
3 – Gauge connection
4 – Pump pressure regulator
5 – Vacuum gauge connection
6 – Screws fixing air-damper
7 – Air-damper
8 – Combustion head adjustment screw
9 – Lock-out lamp and reset button
10 – Flange with insulating gaskets
2095
464 M
8 – 17 kg/h
-
Gas oil, max. viscosity at 20 °C: 6 mm
Single phase, 230 V ± 10%
Run current 1.4 A – 2750 rpm – 288 rad/s
5 µ F
Secondary 8 kV – 16 mA
Pressure: 7 – 15 bar
0.32 kW
Fig. 1
7
6
6
10
D5399

BURNER EQUIPMENT

Quantity
2
1
4
1
1
1
1
GB
95 – 202 kW
2
/s
~
50Hz
2
Description
Flexible pipes with nipples
Flange with two insulating gaskets
Screws and nuts for flange
Hinge
Screw with two nuts for flange
Grommet
ENGLISH
8
1
5

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

464m3452782

Tabla de contenido