3. TRANSPORT, PACKAGING AND STORAGE

3.1 Inspection after transport

Verification of the absence of damage and the integrity of the device must be carried out upon receipt of the
package. In case of identification of damage due to transport, refuse or accept the product delivered only
under reserve*. A complaint detailing the defects observed must then be made. The perception of damages
is only possible in the event of a complaint formulated within the time limits provided, ie 24-48 hours at the
most.
*written on the right paper or digital delivery from the carrier.

3.2 Packaging

The packaging of the device must be kept in the event of a move, or for a return to the after-sales service.
The interior and exterior packaging must be completely removed before using the device. The standards in
force in your country concerning the protection of the environment must be respected before destroying the
packaging.
3.3. Storage
WARNING
The storage of the device in stock can be done but only in its original closed packaging.
Storage can be carried out under these conditions:
• Storage in a dry, non-humid place
• Sheltered from the sun
• Control of stock for more than 2 months (general condition of the device and all the elements that make it
up)
• No material shaking
• Storage in a closed room and not outside.

4. MATERIAL CHARACTERISTICS

* Subject to change
Model
Dimensions
plates
Electrical data
Dimensions
W 484 x D 559 x H 354 mm W 519 x D 592 x H 354 mm W 720 x D 706.5 x H 354mm
Weight
CPAST480
480 x 306mm
2800W / 230V
23.50Kg
CPAST520
515 x 340mm
3600W / 230V
29kg
CPAST700
700 x 400mm
7000W / 400V
45.5kg