Check Instructions; Disconnection, Storage And Transport - Permobil Smart Check Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 12

Check Instructions

Perform a Check after completing Setup (Smart Setup or Optional Setup).
Warnings:
- Perform a Check frequently, at least once a day!
- The cover used during Setup must be the same cover used during Check.
- Perform a Check when there is a significant change in altitude.
How to Perform a Check:
1. You should be in your usual sitting position.
2. Press the Check Button.
3. Refer to the Check Table below.
Check Table
Notes: After you perform a Check, you may choose to perform a Hand Check to become familiar with your inflation range. See the "Hand Check
Guide." • You may be able to add or remove a small amount of air and still be at your cushion inflation setting. Smart Check saves your cushion
inflation setting with some room for adjustment.
Light
Status
The cushion is within the saved
inflation setting.
Light
Possible Causes
Your weight may be unevenly
distributed
The quick disconnect is not securely
attached to the cushion.
The cushion needs more air.
The cushion or the quick disconnect
on the cushion has a slow leak.
Light
Cause
The cushion has too much air.

Disconnection, Storage and Transport

To Disconnect Smart Check from the Cushion: Press down on the gray latch, then separate.
Storage or Transport: Disconnect Smart Check from the cushion. Clean and disinfect the product. When not in use, place
Smart Check in a safe, accessible location (for example, the storage case provided with Smart Check), to protect the device
from moisture, contaminants and damage. After storing or transporting, inspect the product to ensure it was not damaged
(see "Troubleshooting"), and follow the instructions for product use.
Smart Check Operation Manual
Action
No further action is required.
Action
Perform a weight shift to circulate air in the cushion, then press the Check Button to get
a new reading.
Make sure the connection is secure, then press the Check Button to get a new reading.
See "Troubleshooting" in this manual.
Open the valve and add more air to the cushion (6 to 10 pumps). Close the valve. Press
the Check Button to get a new reading. Repeat as needed.
Warning: If you are unable to make adjustments on your own, discontinue use
until assistance is available.
See "Troubleshooting" in the manual provided with the Sensor Ready Cushion or the
Hybrid Elite Cushion, or contact Customer Support.
Action
Open the valve and remove air from the cushion until you see the green light. Close the
valve.
Warning: If you are unable to perform this task, seek assistance.
5
Symbols and Lights for Check
Setup
Button
Red Light
"Remove Air.
See the Check Table."
Green Light
"Within the saved
inflation setting."
Red Light
"Action required. See
the Check Table."
Check