Descargar Imprimir esta página

Bosch NGMP077UC Instrucciones De Instalación página 15

Publicidad

Idiomas disponibles

Idiomas disponibles

Flame
Image
Soft blue
Conversion to LP gas
5 Conversion to LP gas
Your appliance is equipped for use with natural gas on de-
Conversion to LP gas
livery. It can be converted to LP gas supply.
The components required for conversion to LP gas are
contained in the LP conversion kit included with this appli-
ance, or are available from Customer Service.
→  "Customer Service", Page 17
Only a qualified technician or installer is authorized to con-
vert the appliance to another gas type.
Before carrying out the conversion, turn off the electricity
and gas supply.
5.1 Converting the pressure regulator
WARNING
Turn off the electricity and gas supply before carrying out
the conversion.
Locate the pressure regulator on the bottom right end of
1.
the appliance.
Measure
Normal for natural gas
Remove the hexagon shaped conversion cap from the
2.
regulator. Make sure not to dislodge the gasket
the cap or the spring
Grasp the plastic orifice stem
3.
fully from the conversion cap
into an indent in the cap and may require a strong pull
to remove. It may be helpful to gently "rock" the plastic
stem while pulling it from the metal cap.
Rotate the stem 180°
4.
a Confirm that the button end of the orifice stem is away
from the conversion cap.
a Confirm that the letters "LP" on the orifice stem are up-
side down when the conversion cap is set flat on its
head.
Snap the orifice stem back in place in this position in-
5.
serting it into the indent in the conversion cap
Insert the hexagon cap back into the regulator and
6.
tighten, do not over-tighten.
Conversion to LP gas en-us
inside the regulator.
firmly and pull it force-
. The stem snaps snugly
⁠ .
⁠ .
on
15

Publicidad

loading