2. VERIFY UNDERSINK MOUNTING LOCATION
Measure 22" from the base of the cabinet, and mark the
mounting location for the top of the filter head. Measure
13" for the width required for the H-1200 System with dual
cartridges. Make sure there is adequate space above the
head to open and close the shut-off valve and to avoid
crimping the water line tubing. Also, make sure your chosen
location offers easy access for future cartridge changes.
Width
DIMENSION
H-1200
13"
NOTE: The head and cartridge must be mounted in the
vertical position, with the cartridge hanging down.
3. MOUNT FILTER HEAD UNDER SINK
A. Identify Dual Filter Head and Shut Off Valve (EV309860).
B. Apply Plumbers Tape to the threads on the inlet (left)
side of the Head. Screw on the new Shut Off Valve
and hand tighten. Repeat for the Stainless Coupler
(EV312350) for the outlet (right) side of the Head.
C. Apply Plumbers Tape to the threads of the Outlet
Elbow Fitting (black band). Screw into the outlet of
the Stainless Coupler. Wrap tape in direction of the
threads to ensure a tight fit and avoid small leaks.
D. Securely mount the filter head on the cabinet wall
using the enclosed mounting screws and washers.
4. Go to page 5 and follow Basic Installation Instructions,
Steps 4, 5, and 6, to complete the H-1200 System
installation.
CLAIMS & NOTES
This installation must comply with all applicable state and
local regulations.
Do not use with water that is microbiologically unsafe or
unknown quality without adequate disinfection before or
after the system. Systems certified for cyst reduction may be
used on waters that may contain filterable cysts.
Spent adsorption media will not be regenerated and used.
If adsorption media is affected by chlorine, water supply
should be treated to remove chlorine prior to entering filter.
Testing was performed under standard laboratory
conditions, actual performance may vary.
EPA Est. No. 002623-IL-002
The H-54, H-300, H-104, H-300-HSD, & H-1200 are
Tested and Certified by NSF International against CSA
B483.1 and NSF/ANSI 42 and 53 for the claims specified
on the Performance Data Sheet.
C
US
The H-300-NXT is Tested and Certified by NSF
International against CSA B483.1 and NSF/ANSI 42, 53
and 401 for the claims specified on the Performance
C
US
Performance Data Sheet.
Height
Depth
22"
5"
2
Dual Filter Head
3
B
The H-1200 is certified by IAPMO R&T against NSF/ANSI
53 for the reduction of perfluorooctanoic acid (PFOA)
and perfluorooctane sulfonate (PFOS).
EVERPURE
22"
Shut Off Valve
A
C
D
H-Series Water Filtration Systems
• 7