English
2. General information
The user instructions as per this booklet refer to the Cordivari Design
electric towel warmer model Window 1100 E.
RF remote control
RF control
Pair
open handle
The exclusively designed electric Window 1100 towel warmer
combines aesthetics and functionality and promotes a rational
use of space in the room where it is installed. In fact, it is
equipped with a heated movable handle, which can be opened
when needed, acting as a support for heating towels, or remain
closed, when this function is not required, reducing the space
occupied and emphasising the aesthetics. The handle opening
and closing is manual. The handle is held in the two positions
(open/closed) by gas springs. The vertical parts of the handle
and the two vertexes (A) are not heated. Conscious use of the
product in accordance with the warnings given in section 1.0
of this document is recommended in order to avoid crushing
and/or injury to the hand or fingers. The maximum weight that
can be placed on the handle, or it will be closed, is 5 kg. The
product is managed by radio frequency electronics consisting
of two elements.
The power unit is located at the rear right part of the product,
and the RF remote user interface allows to set and programme
the desired parameters and/or functions.
3. Technical features
•
Supply voltage 230 Vac 50 Hz.
•
Maximum power 450 W.
•
IP44 protection rating IP44.
•
Electrical insulation class: Class II, after installation under
the responsibility of the installer.
•
Dry heating element positioned on the radiator body and on
the movable attachment (handle)
•
Consumption in standby mode: < 0.5 W.
•
Electronic PID (Proportional-Integral-Derivative) controller,
activated by a relay+triac.
•
Radio Frequency: 2.4035 Ghz / 2.4055 Ghz / 2.4075 Ghz
•
Maximum RF transmitter power: <1mW
•
Receiver category: III
•
Power supply cable:
• Version with Schuko plug L 1000 mm
• Version with Fil Pilote L 800 mm without plug - 3 conductors
The black cable is a communication cable that can only be
closed handle
dimensions in
mm
used in France. It cannot be grounded. It must always
be protected.
•
Ambient temperature from 0°C to +40°C
•
Humidity: max. 85% at 25°C
•
Storage temperature from -20°C to +60°C
4. User information
To clean painted radiators, use only a non-abrasive cloth
soaked in water.
Never use detergents or aggressive substances. Avoid any
other basic or acidic solution, chemical, industrial or other
substances, aggressive or corrosive substances (bleach,
ammonia, baking soda...). Do not use abrasive cloths or
sponges.
5. Installer information
This product is subject to the general warranty conditions set
forth in the current official Cordivari catalogue. The warranty is
valid from the date of delivery and is void if the production batch
label is tampered with and/or removed. The warranty applies
after the examination of defects and their causes. The material
to be replaced or repaired shall be delivered ex-warehouse at
the dealer. The commitment to provide the warranty is subject to
the conditions and requirements described below.
The radiator has not been damaged during transport, handling
or installation and no repair and/or tampering has been carried
out by third parties without express authorisation. Before
installation, the material has been stored in good conditions and
under shelter form the weather. Product installation must be
carried out by qualified personnel and in compliance with these
instructions and all national and local regulations concerning
installation and safety. Do not place the radiators in rooms
with chlorine vapours or corrosive fumes, e.g. pools, saunas,
thermal pools.
6. Positioning in bathrooms
Since Cordivari electric radiators are provided with a heating
element having Class II insulation and IP44 minimum protection
rating, they can be positioned in hazardous zone 3 (see figure).
In any case, always refer to national installation regulations.
The power socket and the differential switch must be positioned
in zone 3 and no electric control element must be accessible by
a person using the shower or the bath tub.
ZONE 1
ZONE 2
ZONE 3
Position the radiator so that no obstacle is present at a minimum
distance of 100 mm from the equipment.