English
it is possible to set and programme the desired parameters and/
or functions.
3. Technical features
•
Supply voltage 230 V AC 50 Hz
•
IP44 protection rating
•
Electrical insulation: Class II, after installation under the
responsibility of the installer.
•
Consumption in standby mode: < 0.5 W
•
Electronic PID (Proportional-Integral-Derivative) controller,
activated by relay + triac
•
Radio frequency: 2.4035 Ghz / 2.4055 Ghz / 2.4075 Ghz
•
Maximum RF transmitter power: <1 mW
•
Receiver category: III
•
Power supply cable:
• Version with Schuko plug L 1000 mm
• Version with Fil Pilote L 800 mm without plug - 3
conductors
The black cable is a communication cable that can only be
used in France. It cannot be grounded. It must always
be protected.
•
Ambient temperature from 0°C to +40°C
•
Humidity: max. 85% at 25°C
•
Storage temperature from -10°C to +60°C
4. Information for the user
To clean painted radiators, use only a non-abrasive cloth soaked
in water. Never use detergents or aggressive substances.
Avoid any other base or acid solution, chemical, industrial or
other substances, aggressive or corrosive substances (bleach,
ammonia, baking soda...). Do not use abrasive cloths or
sponges.
5. Installer information
This product is subject to the general warranty conditions set
forth in the current official Cordivari catalogue. The warranty is
valid from the date of delivery and is void if the production batch
label is tampered with and/or removed. The warranty applies
after the examination of defects and their causes. The material
to be replaced or repaired shall be delivered ex-warehouse at
the dealer. The commitment to provide the warranty is subject to
the conditions and requirements described below.
The radiator has not been damaged during transport, handling
or installation and no repair and/or tampering has been carried
out by third parties without express authorisation. Before
installation, the material has been stored in good conditions and
under shelter form the weather. Product installation must be
carried out by qualified personnel and in compliance with these
instructions and all national and local regulations concerning
installation and safety. Do not place the radiators in rooms with
chlorine vapours or corrosive fumes, e.g. pools, saunas and
thermal pools.
6. Positioning in bathrooms
Since Cordivari electric radiators are provided with a heating
element having Class II insulation and IP44 minimum protection
rating, they can be positioned in hazardous zone 3 (see figure).
In any case, always refer to national installation regulations.
The power socket and the differential switch must be positioned
in zone 3 and no electric control element must be accessible by
a person using the shower or the bath tub.
ZONE 1
ZONE 2
ZONE 3
7. Wall mounting
Wall mounting of electric radiators must be carried out according
to the instructions contained in the fastening support package
and the figure below. The fastening systems (screws+blocks)
are suitable for compact walls or hollow brick walls.
YES
For walls made of different materials, the installer is responsible
for the use of suitable fastening systems. Do not position the
radiator in front of the power socket. The radiator must not be
installed immediately below a power socket.
8. Connection
Before connection, make sure that the equipment rated voltage
(230 V AC 50 Hz) is equal to the mains voltage, and that the
socket is able to provide the rated current corresponding to the
maximum power of the model selected. Moreover, such socket
must be controlled through a double-pole switch used to switch
the radiator on and off. In case of damage, the power cable of
these radiators can be replaced. Such repair must be carried
out solely and exclusively by the manufacturer.
9. Installing the RF remote control
The RF remote control can be installed either on the wall or
- 24 -
ZONE 0
ZONE 0
NO