Descargar Imprimir esta página

SantaFe ULTRA Serie Instrucciones De Instalación página 12

Publicidad

Idiomas disponibles

Idiomas disponibles

DUCTING TO HVAC SYSTEMS
8
b. Installation in a Basement or Crawlspace
Install a separate 8" return for the Ultra155/205 in a central area of the structure. Duct the supply of the
dehumidifier to the air supply of the HVAC system with a backdraft damper.
Optional:
Duct the supply of the Ultra155/205 to a 8" x 8" x 8" tee/damper with a gravity draft damper,
adjusted to 20% open to the basement. CAUTION: Air takes the path of least resistance. If the upper levels
of the living space are not receiving the appropriate amount of dry air, this damper may need to be adjusted.
When the dehumidifier is not running, there is a chance that air from the basement or crawlspace will make
its way back through the gravity damper and into the living space. If this is of concern, a power damper is
suggested.
Optional Outdoor
Air Intake
12
Santa Fe ULTRA155/205 Installation & Operation Instructions
Motorized
Damper
Ultra Series
IndoorAir Return
Air Handler Supply
Ultra Series Supply
Optional Duct Tee
& Gravity Damper
Santa-Fe-Products.com | 800.533.7533
Backdraft
Damper
Dry Air to
Basement

Publicidad

loading

Este manual también es adecuado para:

Ultra155Ultra205